ULS 100-Watt Series
www.murata-ps.com
Sixteenth-brick DOSA-Compatible,
Isolated DC-DC Converters
Typical units
FEATURES
PRODUCT OVERVIEW
The new ULS 100 Watts series offers output
voltages of 3.3Vout (30A), 5Vout (20A), 6.5Vout
(15A), and 12Vout (8.3A). The ULS sixteenth-brick
series maintains a width of 0.9 inches while still
retaining up to 100 Watt output and full 2250 Volt
DC isolation. The PC-board mount converter fam-
ily accepts 36 to 75 Volts DC inputs and delivers
fixed outputs regulated to within 0.2ꢀ. The ULS
converters are ideal for datacom and telecom ap-
plications, cell phone towers, data centers, server
farms and network repeaters.
ULS outputs may be trimmed within 10ꢀ of
nominal output while delivering fast settling to
current step loads and no adverse effects from
higher capacitive loads. Excellent ripple and noise
specifications assure compatibility to circuits using
CPU’s, ASIC’s, programmable logic and FPGA’s. No
minimum load is required. For systems requiring
controlled startup/shutdown, an external remote
On/Off control may use a switch, transistor or
digital logic. Remote Sense inputs compensate for
resistive line drops at high currents.
Many self-protection features on the ULS series
avoid both converter and external circuit hazards.
These include input undervoltage lockout and
overtemperature shutdown. The output current
limit uses the “hiccup” autorestart technique (i.e.,
the outputs may be short-circuited indefinitely).
Additional features include output overvoltage
protection too.
ꢀ
Industry standard DOSA "Sixteenth-brick"
format and pinout with surface mount option
ꢀ
36-75 Volts DC input range, 3.3, 5, 6.5, and
12 Vdc outputs.
ꢀ
2250 Volt Basic input/output isolation
ꢀ
Up to 100 Watts total output power
ꢀ
High efficiency synchronous rectifier topology
ꢀ
Stable no-load operation with no required
external components
ꢀ
Operating temperature range -40 to +85°C
with derating
The synchronous rectifier topology yields high
efficiency for minimal heat buildup and “no fan”
operation.
ꢀ
Certified to UL 60950-1, CSA-C22.2 No. 234,
EN60950-1 safety approvals, 2nd Edition
ꢀ
Extensive self-protection features
Isolation
F1
+Vin (1)
+Vout (8)
Barrier
• Switching
• Filters
+Sense (7)
External
DC
Power
Source
On/Off
Control
(2)
Controller
and Power
Transfer
• Current Sense
-Sense (5)
Open = On
Closed = Off
(Positive
logic)
Reference and
Error Amplifier
Trim (6)
-Vin (3)
-Vout (4)
Typical topology is shown
Figure 1. Simplified Block Diagram
For full details go to
REG.-Nr. D216
www.murata-ps.com/rohs
www.murata-ps.com/support
SDC_ULS-100 Series.B01.D8 Page 1 of 34