5秒后页面跳转
ULH/ULV400 PDF预览

ULH/ULV400

更新时间: 2024-02-02 15:46:26
品牌 Logo 应用领域
RHOPOINT /
页数 文件大小 规格书
2页 239K
描述
ULV/ULH TYPE

ULH/ULV400 数据手册

 浏览型号ULH/ULV400的Datasheet PDF文件第2页 
Tel : + 44 (0) 1883 717988  
Fax : +44 (0) 1883 712938  
/
ULV/ULH TYPE (UL® Approved)  
The ULV(V=vertical & ULH(H=horizontal) models are UL approved metal-clad, wire-wound high-power resistors designed for  
industrial and other applications. Our extruded aluminium housing provides rugged and strong protection. These models are  
available with flying leads or Tab terminals and can be ordered with inductive or non-inductive windings. To conform to UL  
safety requirements, ULV/ULH models differ from IRV/IRH models in that: The resistance range is smaller, the flying leads  
are UL approved and the dielectric strength depends on the ohmic value.  
GENERAL SPECIFICATIONS  
Resistance Range [ohms]  
Wattage  
Non-  
Inductive  
Rating  
on  
Resistance  
Tolerance  
Inductive  
Model  
Tab  
Flying  
leads  
Tab  
Flying  
Heat Sink  
terminals  
0.1-375  
0.1-281  
0.1-225  
0.1-187  
0.1-150  
0.1-450  
0.1-300  
0.1-225  
0.1-180  
terminals  
0.1-180  
0.1-110  
0.1-225  
0.1-187  
0.1-150  
0.1-450  
0.1-300  
0.1-225  
0.1-180  
leads  
ULH/ULV60  
ULH/ULV80  
ULH/ULV100  
ULH/ULV120  
ULH/ULV150  
ULH/ULV200  
ULH/ULV300  
ULH/ULV400  
ULH/ULV500  
60  
80  
0.1-400  
0.1-910  
0.1-1.1K  
0.1-1.3K  
0.1-1.6K  
0.1-2.2K  
0.1-2.7K  
0.1-4.3K  
0.1-6.8K  
0.1-180  
0.1-110  
0.1-240  
0.1-300  
0.1-390  
0.1-1K  
0.1-1.5K  
0.1-2.2K  
0.1-3K  
100  
120  
150  
200  
300  
400  
500  
+-2.0(G)  
+-5.0(J)  
+-10(K)  
CHARACTERISTICS  
Values in [ ] mean change in ohms after test  
Temperature Range  
-55C to 200C  
Insulation Resistance  
Dielectric Strength  
Temp. Coefficient  
Short Time Overload  
Moisture Resistance  
Thermal Shock  
20M ohms minimum  
[1000V+(rated voltage×2)] / min.  
+-260ppm/C maximum  
+-[2%+0.05ohms]  
+-[3%+0.05 ohms]  
+-[2%+0.05 ohms]  
+-[1%+0.05 ohms]  
+-[3%+0.05 ohms]  
+-[5%+0.05 ohms]  
60W:5Xwattage rating-5second, 80to500W: 10Xwattage rating-5seconds  
40C, 95% RH, DC100V case to terminal (500hrs.)  
wattage rating 30min., -25C, 15minutes  
Vibration  
10Hz-55Hz-10Hz (1min.),2hrs. each direction  
40C,95%RH,0.1Xwattage rating, 1.5h.on,30min.off,500 hours  
Wattage rating 1.5h. on, 30min. off, 500hours  
Moisture Load Life  
Load Life  
Applied voltage : AC RMS voltage  
SURFACE TEMPERATURE INCREASE VERSUS POWER LOAD  
A mid-point bracket is required for 150, 300, 500W models to ensure sufficient contact with the heat sink.  
Website : http://www.rhopointcomponents.com Email: sales@rhopointcomponents.com