UFEC60 SERIES
CHASSIS-MOUNT DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 60 Watts
FEATURES
• NO MINIMUM LOAD REQUIRED
APPLICATIONS
• WIRELESS NETWORK
• TELECOM/DATACOM
• 1600VDC INPUT TO OUTPUT ISOLATION
• APPLICATION OF CHASSIS-MOUNT DC/DC CONVERTERS
• SCREW TERMINALS FOR INPUT AND OUTPUT CONNECTIONS
• INTERNAL INPUT FUSE PROTECTION
• INTERNAL OUTPUT LED INDICATOR
• MEET EN55022 CLASS B
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1
• CE MARKED
• COMPLIANT TO RoHS II & REACH
REVERSE
POLARITY
PROTECTION
1600VDC REMOTE
ISOLATION CONTROL
FUSE
INCLUDED
INRUSH
LIMIT
UVP
OCP
SCP
OVP
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25 otherwise noted
Maximum
Capacitor Load (1)
Output Current
@Full Load
Input Current
@ No Load
Input Range
Output Voltage
Efficiency
Model
Number
VDC
VDC
3.3
5
12
15
24
3.3
5
A
14
12
5
mA
102
132
57
72
85
100
92
35
40
%
µF
36000
20400
3550
2300
885
36000
20400
3550
2300
885
UFEC60-24S3P3
UFEC60-24S05
UFEC60-24S12
UFEC60-24S15
UFEC60-24S24
UFEC60-48S3P3
UFEC60-48S05
UFEC60-48S12
UFEC60-48S15
UFEC60-48S24
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
87
88
89
89
88
87
88
89
89
88
4
2.5
14
12
5
4
2.5
12
15
24
60
PART NUMBER STRUCTURE
UFEC60 - 48
Voltage
S
Quantity
05 -
N
EC
Assembly Option
Input
Series Name
Output
Output
Voltage
(VDC)
Remote Control
Option
(VDC)
24: 18~36
48: 36~75
S: Single
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
ꢀ: Positive logic
N: Negative logic
ꢀ: No Assembly Option
EC: Enclosed Mounting Type
DR: Din Rail Mounting Type
ED: Enclosed & Din Rail Mounting Type
www.PDUKE.com
1
2014/4/30