UF2001 - UF2007
2.0A ULTRA-FAST RECTIFIER
Features
·
·
·
Diffused Junction
Ultra-Fast Switching for High Efficiency
High Current Capability and Low Forward
Voltage Drop
A
B
A
·
·
·
Surge Overload Rating to 60A Peak
Low Reverse Leakage Current
Plastic Material: UL Flammability
Classification Rating 94V-0
C
D
Mechanical Data
DO-15
Min
·
·
Case: Molded Plastic
Terminals: Plated Leads Solderable per
MIL-STD-202, Method 208
Dim
A
Max
25.40
5.50
¾
B
7.62
0.889
3.60
·
·
·
·
Polarity: Cathode Band
Marking: Type Number
Weight: 0.4 grams (approx.)
Mounting Position: Any
C
0.686
2.60
D
All Dimensions in mm
@ TA = 25°C unless otherwise specified
Maximum Ratings and Electrical Characteristics
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
UF
UF
UF
UF
UF
UF
UF
Characteristic
Symbol
Unit
2001
2002
2003
2004
2005
2006
2007
1000
700
VRRM
VRWM
VR
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
50
100
70
200
140
400
600
420
800
560
V
VR(RMS)
IO
RMS Reverse Voltage
35
280
2.0
V
A
Average Rectified Output Current
(Note 1)
@ TA = 50°C
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave Superimposed on Rated Load
(JEDEC Method)
IFSM
60
A
Forward Voltage
@ IF = 2.0A
VFM
IRM
1.0
1.3
1.7
V
Peak Reverse Current
at Rated DC Blocking Voltage
@ TA 25°C
=
5.0
100
mA
@ TA = 100°C
trr
Cj
Reverse Recovery Time (Note 3)
50
50
75
30
ns
pF
Typical Junction Capacitance (Note 2)
RqJA
Tj, TSTG
Typical Thermal Resistance Junction to Ambient
Operating and Storage Temperature Range
50
K/W
°C
-65 to +150
Notes:
1. Valid provided that leads are maintained at ambient temperature at a distance of 9.5mm from the case.
2. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
3. Measured at IF = 0.5A, IR = 1.0A, Irr = 0.25A. See figure 5.
DS25007 Rev. A1-2
1 of 2
UF2001 - UF2007