5秒后页面跳转
UCL01L PDF预览

UCL01L

更新时间: 2024-01-31 19:56:43
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
4页 21K
描述
SPEZISALREINIGER ULTRACLENS 1 LIT DOSE

UCL01L 数据手册

 浏览型号UCL01L的Datasheet PDF文件第2页浏览型号UCL01L的Datasheet PDF文件第3页浏览型号UCL01L的Datasheet PDF文件第4页 
PAGE:  
1 of 3  
PRINT DATE:  
REF:  
SAFETY DATA SHEET  
06/08/1997  
ULC200/400D/S  
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE  
COMPANY/UNDERTAKING  
Product name:  
ULTRACLENS  
Product code:  
Supplier:  
ULC200/400D/S  
ELECTROLUBE  
H.K. Wentworth Ltd.,  
Wentworth House, Blakes Road,  
Wargrave, Berkshire, RG10 8AW, United Kingdom.  
Fax No: 0118 9403084  
Emergency telephone number:  
0118 9404031  
2. COMPOSITION/INFORMATION ON INGREDIENTS  
Identification of the preparation  
Chemical Name  
CAS-No  
5131-66-8  
124-38-9  
-
EEC-No  
Class  
Weight %  
< 20  
3-BUTOXYPROPAN-2-OL  
carbon dioxide (CO2)  
Hydrocarbons  
225-878-4  
Xi; R36/38  
-
-
-
-
3 - 5  
> 75  
3. HAZARDS IDENTIFICATION  
Most important hazards:  
Specific hazards  
Flammable  
High concentration of vapours may cause irritation to eyes and  
respiratory system and produce narcotic effects. Prolonged skin  
contact may defat the skin and produce dermatitis.  
4. FIRST AID MEASURES  
General advice:  
Inhalation:  
Remove from exposure, lie down.  
Move to fresh air. Consult a physician after significant exposure.  
Skin contact:  
Eye contact:  
Wash off immediately with soap and plenty of water. Treatment : skin cream.  
Rinse immediately with plenty of water for at least 15 minutes. Consult a  
physician for severe cases.  
Ingestion:  
Immediately give large quantities of water to drink. If symptoms persist, call a  
physician.  
5. FIRE-FIGHTING MEASURES  
Suitable extinguishing media:  
Extinguish with dry chemical or foam, carbon dioxide (CO2).  
Extinguishing media which must not be used for safety reasons:  
Do not use water jet.  
Specific hazards:  
Fire or intense heat may cause violent rupture of packages.Water mist  
may be used to cool closed containers.  
Special protective equipment for firefighters:  
In the event of fire, wear self-contained breathing apparatus.  
6. ACCIDENTAL RELEASE MEASURES  
Personal precautions:  
Remove all sources of ignition.  
Environmental precautions:  
Methods for cleaning up:  
Do not contaminate surface water.  
Soak up with inert absorbent material. Shovel into suitable  
container for disposal.