5秒后页面跳转
UCC3918PWP PDF预览

UCC3918PWP

更新时间: 2024-11-19 23:39:07
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
7页 196K
描述
Power Control/Management

UCC3918PWP 数据手册

 浏览型号UCC3918PWP的Datasheet PDF文件第2页浏览型号UCC3918PWP的Datasheet PDF文件第3页浏览型号UCC3918PWP的Datasheet PDF文件第4页浏览型号UCC3918PWP的Datasheet PDF文件第5页浏览型号UCC3918PWP的Datasheet PDF文件第6页浏览型号UCC3918PWP的Datasheet PDF文件第7页 
application  
INFO  
UCC2918  
UCC3918  
available  
Low On Resistance Hot Swap Power Manager  
FEATURES  
DESCRIPTION  
Integrated 0.06Power  
The UCC3918 Low on Resistance Hot Swap Power Manager provides complete  
power management, hot swap capability, and circuit breaker functions. The only  
components needed to operate the device, other than supply bypassing, are a tim-  
ing capacitor, and 2 programming resistors. All control and housekeeping functions  
are integrated, and externally programmable. These include the fault current level,  
maximum output sourcing current, maximum fault time, and startup delay. In the  
event of a constant fault, the internal fixed 3% duty cycle ratio limits the average  
output power. The IFAULT pin allows linear programming of the fault level current  
from 0A to 4A.  
MOSFET  
3V to 6V Operation  
External Analog control of  
Fault Current from 0A to 4A  
Independent Analog Control  
of Current Limit up to 5A  
Fast Overload Protection  
Uni-directional Switch  
Fast overload protection is accomplished by an additional overload comparator. Its  
threshold is internally set above the maximum sourcing current limit setting. In the  
event of a short circuit or extreme current condition, this comparator is tripped,  
shutting down the output. This function is needed since the maximum sourcing cur-  
rent limit loop has a finite bandwidth.  
Minimal External Components  
1µA ICC when Disabled  
Programmable On Time  
Programmable Start Delay  
Fixed 3% Duty Cycle  
When the output current is below the fault level, the output MOSFET is switched on  
with a nominal resistance of 0.06. When the output current exceeds the fault level  
or the maximum sourcing level, the output remains on, but the fault timer starts  
charging CT. Once CT charges to a preset threshold, the switch is turned off, and  
remains off for 30 times the programmed fault time. When the output current  
reaches the maximum sourcing level, the MOSFET transitions form a switch to a  
constant current source.  
(continued)  
BLOCK DIAGRAM  
CHARGE  
PUMP  
VIN  
VIN  
VIN  
1
2
3
OVERLOAD  
COMPARATOR  
REVERSE  
COMPARATOR  
+
20mV  
V
OUT  
+
CURRENT SENSE  
H = OPEN  
9
8
IMAX  
MAXIMUM  
CURRENT  
LEVEL  
OVERCURRENT  
COMPARATOR  
14 VOUT  
15 VOUT  
16 VOUT  
CURRENT  
FAULT LEVEL  
ON TIME  
CONTROL  
IFAULT  
3% DUTY  
CYCLE  
THERMAL  
SHUTDOWN  
1.5V  
+
INTERNAL  
BIAS  
7
SHTDWN  
5
4
13  
12  
10  
6
HEAT SINK GND  
PINS  
GND  
CT  
FAULT  
UDG-99153  
SLUS384A - NOVEMBER 1999  
Powered by ICminer.com Electronic-Library Service CopyRight 2003  

与UCC3918PWP相关器件

型号 品牌 获取价格 描述 数据表
UCC3918PWPTR TI

获取价格

IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO24, POWER, SOP-24, Power Management Circuit
UCC3919 TI

获取价格

3V to 8V Hot Swap Power Manager
UCC3919D TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919DG4 TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919DTR TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919DTRG4 TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919N TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919PW TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919PWG4 TI

获取价格

3-V TO 8-V HOT SWAP POWER MANAGER
UCC3919PWTR ETC

获取价格

Power Control/Management