400W True Sine Wave DC-AC Power Inverter
TS-400 series
Features :
True sine wave output (THD<3%)
High surge power up to 800W
High efficiency up to 88.5%
Thermostatically controlled cooling fan
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
E13
SPECIFICATION
MODEL
TS-400-112
TS-400-124
TS-400-148
TS-400-212
TS-400-224
TS-400-248
RATED POWER
400W
MAXIMUM OUTPUT POWER 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.)
Factory setting set at 110VAC
Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W
60 0.1Hz 50/60Hz selectable by setting button
True sine wave (THD<3%) at rated input voltage
Note.2 3.0% at rated input voltage
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1Hz 50/60Hz selectable by setting button
OUTPUT
FREQUENCY
WAVEFORM
AC REGULATION
FRONT PANEL INDICATOR
BAT. VOLTAGE
Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
24V
48V
24V
48V
12V
12V
VOLTAGE RANGE (Typ.)
DC CURRENT (Typ.)
10.5 ~ 15VDC
40A
21 ~ 30VDC
20A
42 ~ 60VDC
10A
10.5 ~ 15VDC
40A
21 ~ 30VDC
20A
42 ~ 60VDC
10A
1.25A
INPUT
NO LOAD CURRENT DRAW (Typ.)
OFF MODE CURRENT DRAW
0.63A
0.32A
1.25A
0.63A
0.32A
1mA
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE
Note.1 84.5%
86%
87%
86%
87.5%
88.5%
Open & sealed Lead Acid
40A*2
40A*1
20A*1
45 4%
42 4%
40A*2
40A*1
20A*1
45 4%
42 4%
BATTERY
INPUT
PROTECTION
11.3 4%
22.5 4%
21 4%
11.3 4%
10.5 4%
22.5 4%
21 4%
BAT. LOW ALARM
BAT. LOW SHUTDOWN
BAT. POLARITY
10.5 4%
By internal fuse open
75
5
70
5
85
5
75
5
70
5
85
5
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
OUTPUT
PROTECTION
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
OVER LOAD (Typ.)
GFCI PROCTECTION
Protection type : Shut down o/p voltage, re-power on to recover
Optional (Only type F)
None
Open : Normal work ; Short : Remote off
-10 ~ +40 @ 100% load ; +60 @ 50% load
20% ~ 90% RH non-condensing
FUNCTION REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
LVD
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to UL458
None
None
EN60950-1
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
SAFETY & WITHSTAND VOLTAGE
EMC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,8
Compliance to FCC class A
None
104.7K hrs min. MIL-HDBK-217F (25oC)
OTHERS
NOTE
DIMENSION
PACKING
205*158*67mm (L*W*H)
1.73Kg; 6pcs/11.4Kg/1.55CUFT
1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation is tested at 13V/26V/52V input voltage.
File Name:TS-400-SPEC 2012-03-20