5秒后页面跳转
TR3/SFT10.0A PDF预览

TR3/SFT10.0A

更新时间: 2024-11-20 23:37:35
品牌 Logo 应用领域
其他 - ETC /
页数 文件大小 规格书
2页 78K
描述
Fuse

TR3/SFT10.0A 数据手册

 浏览型号TR3/SFT10.0A的Datasheet PDF文件第2页 
®
Bu s s m a n n  
S MD TRON® S u rfa c e Mo u n t Fu s e s  
Fo r .1 7 0 ” x .2 9 4 ” (4 .3 2 m m x 7 .4 7 m m ) Fu s e s  
S FT  
R
Time-Current Characteristic CurvesÐAverage Melt  
(Full Size Curves Available)  
AMPERE RATING  
10  
Catalog Symbol:  
SFT  
Characteristics: Fast-Acting, Current-Limiting  
Construction: Solid Matrix  
Dimensional Data  
.29" (± .015)  
(7.47 mm) (± .006)  
1
.17" (± .015)  
(4.32 mm) (± .006)  
.12" (± .015)  
(3.05 mm) (± .006)  
.1  
(1.27 mm)  
.05"  
.09" (± .015)  
(2.29 mm) (± .006)  
*Packaging & Ordering Information:  
SFT  
(See Table)  
Product  
Symbol  
Rated Current  
.01  
Package Code  
CURRENT IN AMPERES  
TR/  
500 pcs., on a 7” reel, 16mm tape width.  
TR1/ 2000 pcs., on a 13” reel, 16mm tape width.  
TR2/ 500 pcs., on a 7” reel, 12mm tape width.  
TR3/ 2500 pcs., on a 13” reel, 12mm tape width.  
Weight = .6 lbs/500  
Time-Current Characteristics:  
Percent of Rating  
Rated  
Current  
0-10  
100%  
250%  
5 sec. (max)  
4 hrs. (min)  
*See page 2.  
Electrical Characteristics  
Typical Voltage  
Drop2 Volts at  
100% Rated  
Current  
Agency**  
Approvals  
Rated  
Interrupting  
Rating1  
Pre-arcing  
I2T (A sec)  
Typical Total Clearing3  
2
2
Rated  
Current5  
63mA  
125mA  
250mA  
375mA  
500mA  
750mA  
1
1.5  
2
2.5  
3
3.5  
4
5
7.0A  
10.0A  
12.5A  
Voltage  
I2T (A sec)  
AC (Max.)  
DC (Max.)  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
90V  
AC  
DC  
AC  
DC  
AC  
DC  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
125V  
60V  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
50A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
300A  
-5  
-6  
-4  
-6  
-5  
-5  
-4  
7.49 x 10  
3.17 x 10  
4.46 x 10  
1.72 x 10  
.0099  
.0302  
.0784  
.1775  
.3355  
.4980  
.8855  
1.7264  
1.64  
3.79  
5.1 x 10  
2.0 x 10  
6.29 x 10  
2.67 x 10  
4.63 x 10  
2.77 x 10  
.0076  
.8  
.75  
.66  
.525  
.12  
-4  
-4  
-3  
-5  
-4  
-4  
-3  
2.18 x 10  
4.18 x 10  
5.74 x 10  
2.59 x 10  
.0114  
-5  
3.8 x 10  
2.27 x 10  
.0069  
.0204  
.0651  
.1390  
.2419  
.3812  
.6785  
1.2912  
.518  
-4  
.0345  
.0246  
.20  
.0891  
.0811  
.170  
.145  
.130  
.155  
.135  
.125  
.114  
.130  
.090  
.2383  
.1574  
.4359  
.2664  
.6355  
.4696  
1.0740  
2.3779  
1.97  
.7829  
1.3556  
.573  
60V  
48V  
90V  
60Vꢀ  
1.06  
4.04  
3.92  
1.67  
15  
20  
4.28  
**Approvals: UL Recognition, Std. 248-14, Guide #JDYX2, File #E19180; CSA Certification, C22.2 No. 248.14, Class #1422-01, File #53787.  
NOTE: SFT 12.5A is UL recognized on AC Only.  
1. Interrupting ratings were measured at 100% power factor on AC, and a time constant less than 1ms on DC.  
2. Voltage drop was measured at 25°C ± 3°C ambient temperature at rated current with device mounted on a circuit trace.  
3. I2t measured at 50 amp, 125 VAC, .95PF, random closing angle; 300 amps, 125 VDC, TC<1ms.  
4. Electrical characteristics for 12.5 amp to be determined.  
5. Device designed to carry 125% of rated current for one hour minimum. An operating current of 80% or less of rated current is recommended, with further derating  
required at elevated ambient temperatures.  
CE logo denotes compliance with European Union Low Voltage Directive  
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact  
Bussmann Application Engineering at 314-527-1270 for more information.  
Form No. SFT  
Page 1 of 2  
BIF Doc #2005  
12-28-98  
SB98107  
Rev. A