HALOGEN
Chip™ Fuses
3216FF Series, Fast-Acting
HF
Pb
FREE
Ordering
• Specify packaging and product code
(i.e., TR/3216FF250-R)
Soldering Method
• Wave Immersion: 260°C, 10 sec max.
• Infrared Reflow: 260°C, 30 sec max.
Electrical Characteristics
% of Amp Rating
Amp Rating
250mA - 30A
1.25A - 3A
250mA - 3A
4A - 7A
Opening Time
Description
• Fast-acting surface mount fuse
• Ratings up to 30 amps
• Excellent temperature and cycling characteristics
• Compatible with reflow and wave solder
Agency Information
• UL Recognition Guide JDYX2 & File E19180.
• CSA Component Acceptance: 053787 C 000 &
Class No: 1422 30.
100%
200%
250%
350%
350%
4 Hrs. Min.
60 Sec. Max.
5 Sec. Max.
1 Sec. Max.
5 Sec. Max.
10A - 30A
Dimension - mm/inches
Drawing Not to Scale
•
Recognition File: E19180, Guide JDYX2/JDYX8
Environmental Data
• Thermal Shock: MIL-STD-202, Method 107,
Test Condition B (-65°C to 125°C)
Recommended Pad Layout - mm (in)
• Vibration: MIL-STD-202, Method 204,
Test Condition C (55Hz - 2kHz, 10G)
• Moisture Resistance: MIL-STD-202, Method 106,
10 day cycle
• Solderability: ANSI/J-STD-002, Test B
• Additional resistance to solder heat teast: MIL-STD-202G Method
210F Condition A
• Operating Temperature: -55ºC to 125ºC
Specifications
Part
Number
Volt Ratings
Vdc
Interrupting Rating*
(amps) AC/DC
Typical DC Cold
Resistance (W)**
3.5000
Typical Melt
I2t (A2S) DC***
0.00038
0.00077
0.00190
0.0053
0.030
0.046
0.093
0.126
0.260
0.275
0.337
0.405
0.534
2.294
3.623
2.0
Typical Voltage
Drop (V)†
1.40
Agency Approvals
Vac
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
UR
CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
cURus
3216FF250-R
3216FF375-R
3216FF500-R
3216FF750-R
3216FF1-R
3216FF1.25-R
3216FF1.5-R
3216FF2-R
3216FF2.5-R
3216FF3-R
3216FF4-R
3216FF4.5-R
3216FF5-R
3216FF6.5-R
3216FF7-R
3216FF10-R
3216FF12-R
3216FF15-R
3216FF20-R
3216FF25-R
3216FF30-R
63
63
63
63
63
63
63
63
63
63
32
32
32
32
32
24
24
24
24
24
24
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1.7500
0.9800
0.5400
0.2190
0.1700
0.1190
0.0660
0.0460
0.0360
0.0180
0.0160
0.0140
0.0086
0.0070
0.0045
0.0039
0.73
0.66
0.63
0.20
0.18
0.18
0.16
0.14
0.13
0.11
0.10
0.09
0.076
0.078
0.062
0.070
0.066
0.060
0.057
0.068
150
150
150
150
250
300
X
X
X
X
X
X
7.0
25.5
48.6
32.0
0.0031
0.0018
0.0014
0.001
43.0
* AC Interrupting Rating measured at rated voltage with a unity power factor; DC Interrupting Rating measured at rated voltage, time constant of less than 50 microseconds, battery source
**Typical DC Cold Resistance measured at 10% of rated current
***Typical Melting I2t measured with a battery bank at rated DC voltage, 10x-rated current, not to exceed IR, time constant of calibrated circuit less than 50 microseconds (6.5A - 30A measured at interrupting rating)
†Typical Voltage Drop measured at rated current after temperature stabilizes. It is recommended that fuses be mounted with ceramic (white) side facing up.
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.