Total Power International, Inc.
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME
AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS
INTERNAL SWITCHING POWER SUPPLIES TPVP200 SERIES
FEATURES:
ꢀ ACCOMMODATE UNIVERSALAC SOURCES
ꢀ MEET IEC 61000-3-2 HARMONIC CORRECTION
ꢀ THIRD-WIRE LOADING SHARING
ꢀ MEET UNIVERSAL SAFETY STANDARDS
ꢀ EMI MEET CISPR PUB.22 CLASS B
ꢀ +5V STAND-BY GREEN POWER
ꢀ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: Molex #5273 V-M connector.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 33A @230Vac.
Input Current: 2.25A @115Vac, 1.0 A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB.22 Class B.
Hold-up Time: 18mS @115Vac & 230Vac.
Power Fail Signal: Installed.
DC OK Signal: Installed in VO1 & VO2.
Power Factor Correction: Meet Harmonic Correction
per IEC 61000-3-2 PF typ. 0.97-0.99.
Output Current: See Ratings Chart.
Output Connector: Molex #5273 V-M connector.
Output Wattage: Convection 150 watts.
With 30 cfm forced air 200W.
Line Regulation: Typ. 0.1%.
Load Regulation: Main O/P VO1: Typ. ±1.0%.
Aux. O/P VO2: Typ. ±1.0%. (Magnetic Amp).
Aux. O/P VO3,4,5: Typ. ±2-3.0%. (P.R.).
Stand-By Green Power: +5V/50mA available.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Available at VO1 & VO2.
Remote Sense: Installed in VO1 & VO2.
Adjustability: Available at VO1 & VO2.
Load Sharing: Active current sharing circuit at VO1.
Overload Protection (OLP): Fully protected against output
overload and short circuit.
Remote Inhibit: Installed. Enable active high.
Over Temperature Protection: Thermostat @ 95°C.
Earth Leakage: Less than 0.75mA.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 65-70%.
Operating Temperature: 0 to +50°C under forced air flow
for full load.
Switching Frequency: Fixed frequency at 70K Hz.
Circuit Topology: PWM fixed-frequency forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. ±0.04%/ °C.
Cooling: 30 cfm air flow is required to deliver
the full power 200W.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Power Density: 3.0 Watts / Cubic Inch.
Construction: U-bracket construction format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free:877-646-0900(US) PH# 978-453-7272 www.total-power.com