TOTAL POWER INT'L
TPSPU65 SERIES
80W Desk Top Switching Power Supplies For I.T.E.
Description:
The TPSPU65 series of AC/DC switching mode power
supplies provide 80 Watts of continuous output power.
All supplies are UL 94V-0 compliant, include IEC-320-C14
input for worldwide applications. All models meet FCC Part-
15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL, C-UL, TUV and CE
requirements. All units are 100% burned in and tested.
Features:
+
+
+
+
+
+
+
+
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single to Quad Output
Output Voltage Available From 3 VDC Thru 48 VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage and Over Load protection
Splash proof
Safety Approvals :
One Year Warranty
P
S
B
E
C
Product Safety
Electrical Characteristics:
Sym.
Vin Input Voltage
Fin Input Frequency
Parameter
Test Conditions
Min. Typ. Max. Unit
90
47
0
264
63
VAC
Hz
W
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
Vin=90 to 264VAC
80
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
1.9
1.5
A
A
Io=Full load, 25°c, Cool start,
Vin=115VAC
Irl Low Line Inrush Current
12
15
A
Io=Full load, 25°c, Cool start,
Vin=230VAC
Irh High Line Inrush Current
26
30
A
Eff Efficiency
Io=Full Load, Vin=230VAC
75
83
0.5
3
88
1
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Transient Response
Thold Hold-Up Time
Io=Full Load
Vin=230VAC
7
%
112
110
132
150
4
%
%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=100VAC
mS
mS
S
16
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3
1
1
2
2
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
Tc Temperature Coefficient All output
%
0.5 0.75
0.04
mA
%/°c
-0.04
Environmental :
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Toper Operating Temperature
Tstg Storage Temperature
0
-40
5
70
85
95
°c
°c
%
Hr
Pd
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
Safety Specifications:
Sym.
Parameter
Test Conditions
Primary to secondary
Primary to ground
Min. Typ. Max. Unit
Dielectric Withstanding Voltage
for Primary to secondary
Vps
4242
2121
VDC
VDC
Dielectric Withstanding Voltage
for Primary to ground
Vpg
Ri Isolation Resistance
Test Voltage = 500VDC
Vin=220VAC
50
B
MW
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
CLASS
CLASS
B
Vin=110VAC