Total Power International, Inc.
15W Desk Top Type
I.T.E. Power Supplies
TPSPU16E SERIES
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
A Stand And Mains AC Power Cord
Optional Output Connector (See page appendix)
Single Output
Class I
Energy Star 2.0, Efficiency level V
2 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
100~240VAC
90~264VAC
47~63Hz
Vin
Application:
Operate Voltage Range
- Ethernet Hub
- Portable Devices
- Charger
Input Frequency
fin
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
See rating chart
See rating chart
See rating chart
Po
Vo
Io
- Monitor
- Set-top Box
- AV Equipment
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Iil
0.4A
0.26A
Iih
15A (max.)
30A (max.)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Ir
Safety Approvals:
72~85%
0.5~1%
3~7%
Nil
Eff
Line Regulation
REG-i
REG-o
OVP
Load Regulation
PS
E
Vin=230VAC
S&E
RT
Over Voltage Protection
RoHS
2002/95/EC
COMPLIANT
Nil.But,Output protected to short circuit conditions
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
OCP Over Current Protection
4mS (max.)
8mS (min.)
2S (max.)
Time of Transient Response
Hold-Up Time
Ttr
Th
Ts
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Start Up Time
Io=Full Load, Vin=100VAC
Vp-p Ripple & Noise(Peak to Peak)
Full Load, Vin=90VAC
1% (max.)
Safety Ground Leakage Current
Ilk
0.75mA (max.)
Vin=240VAC/60Hz
All output
Temperature Coefficient
TC
0.04%/°C
See rating chart
No-Load Power Consumption
No load, Vin=230VAC
Pno
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Primary to secondary
4242VDC (min.)
2594VDC (min.)
Dielectric Withstanding Voltage
for Primary to PE
Vpg
Ris
Primary to PE
Test Voltage=500VDC
(min.)
50M
Isolation Resistance
Note: The Ripple & Noise which is under 3.3VCD at 2% max
Environmental
Operating Temperature
To
Ts
See derating curve
-40~85°C
Storage Temperature
Operating Humidity
0~95%
Ho
Storage Humidity
0~95%
Hr
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
Derate linearly from 100% load at 40°C to 50% load at 70°C
0.1M Hrs (min.)
MTBF
Pd
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com