Total Power International, Inc.
85W LED Power Supply
TPLSU85 SERIES
Features:
Wide Operating Voltage 90 to 305 VAC,47 to 63 Hz
Internal EMI filter
Active Power Factor Correction
C.C. Mode + C.V. Mode
Constant Current: 1.5~4.04A
Constant Voltage: 21~50V
Over Voltage, Over Current, Over Temperature (optional)
Class I
3 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
100~277VAC
90~305VAC
47~63Hz
Vin
Application:
- Outdoor installations
Operate Voltage Range
Input Frequency
fin
Power Factor Correction
Output Power Range
Io=Full load, Vin=90~280VAC
0.90~1.0
PF
Po
Vo
Io
See rating chart
See rating chart
See rating chart
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Io=Full load, Vin=100VAC
1.3A
Iil
Safety Approvals:
Io=Full load, Vin=240VAC
0.5A
Iih
35A (max.)
70A (max.)
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Low Line Inrush Current
High Line Inrush Current
Efficiency
CB
IP67 RoHS
Ir
BAUART
GEPRUFT
TYPE
APPROVED
2002/95/EC
COMPLIANT
86~90%
Eff
Line Regulation
Io=Full Load
0.5~1%
REG-i
UL/c-UL(UL8750:1st edition)
Load Regulation
Vin=230VAC (C.C.)
Vin=230VAC (C.V.)
3%
REG-o
OVP
Load Regulation
3%
TUV(EN/IEC61347-1:2008,
EN/IEC61347-2-13:2006)
Over Voltage Protection
103~105%
103~105%
140~180%
4mS (max.)
8mS (min.)
1S (max.)
1% (max.)
0.75mA (max.)
C.C.
Over Current Protection
Over Current Protection
Time of Transient Response
Hold-Up Time (C.V.)
CE-EMC(EN55015:2006 &
EN61547:1995+A1:2000)
OCP
C.V.
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Ttr
Th
Ts
Start Up Time
Vp-p Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Ilk
Vin=240VAC/60Hz
All output
Temperature Coefficient
TC
0.04%/°C
See rating chart
4242VDC (min.)
No-Load Power Consumption
Dielectric Withstanding Voltage
No load, Vin=230VAC
Primary to secondary
Pno
Vps
Dielectric Withstanding Voltage
for Primary to PE
Vpg
Ris
Primary to PE
2121VDC (min.)
Test Voltage=500VDC
(min.)
50M
Isolation Resistance
Environmental
Operating Temperature
See derating curve
-40~85°C
To
Ts
Storage Temperature
Operating Humidity
Storage Humidity
0~95%
Ho
0~95%
Hr
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
0.1M Hrs (min.)
MTBF
Pd
Derate linearly from 100% load at 60°C to 50% load at 70°C