Total Power International, Inc.
63W U Bracket Type
TPIUU63 SERIES
Industrial Power Supplies
Features:
Wide Operating Voltage 81 to 280 VAC, 47 to 400 Hz or 90 to 420VDC
Internal EMI filter
Single to Quad Output
Size: 3.2"x5"x1.38"
Power Fail Detect (Optional)
Operating temperature -20~70°C
Class I
3 year warranty
Electrical Characteristics:
90~264VAC
Universal Input Voltage
Application:
- Monitor
106~250VDC
81~280VAC
90~420VDC
47~63Hz
Vin
Operating Voltage
- Industrial PC
- Set-top box
- AV equipment
- CCD recorder
Input Frequency
fin
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
See rating chart
See rating chart
See rating chart
Po
Vo
Io
Io=Full load, Vin=100VAC or 160VDC
Io=Full load, Vin=240VAC or 325VDC
1.6A
0.8A
Iil
Safety Approvals:
Iih
Io=Full load, 25°C, Cool start,
Vin=115VAC or 160VDC
35A (max.)
70A (max.)
Low Line Inrush Current
High Line Inrush Current
Ir
Io=Full load, 25°C, Cool start,
Vin=230VAC or 325VDC
BAUART
RoHS
COMPLIANT
GEPRUFT
TYPE
APPROVED
2002/95/EC
Efficiency
Io=Full load, Vin=230VAC or 325VDC
Io=Full Load
70~88%
0.5~1%
Eff
Line Regulation
Load Regulation
Over Voltage Protection
REG-i
REG-o
OVP
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Vin=230VAC or 325VDC
5~6%
112~132%
110~150%
OCP Over Current Protection
Io=Full Load to Half Load,
Vin=100VAC or 140VDC
5mS (max.)
Time of Transient Response
Ttr
Hold-Up Time
Start Up Time
Io=Full Load, Vin=110VAC or 160VDC
Io=Full Load, Vin=100VAC or 140VDC
Full Load, Vin=85VAC or 100VDC
Vin=240VAC/60Hz
16mS (min.)
2S (max.)
Th
Ts
Vp-p Ripple & Noise(Peak to Peak)
1% (max.)
Safety Ground Leakage Current
Ilk
0.45mA (max.)
0.05%/°C
All output
Temperature Coefficient
TC
See rating chart
No-Load Power Consumption
No load, Vin=230VAC
Pno
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Primary to secondary
4242VDC (min.)
2414VDC (min.)
Dielectric Withstanding Voltage
for Primary to PE
Vpg
Ris
Primary to PE
Test Voltage=500VDC
(min.)
50M
Isolation Resistance
Note: The Ripple & Noise which is under 3.3VDC at 2% max
Environmental
Operating Temperature
See derating curve
-40~85°C
To
Ts
Storage Temperature
Operating Humidity
0~95%
Ho
Storage Humidity
0~95%
Hr
Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
Derate linearly from 100% load at 50°C to 50% load at 70°C
0.1M Hrs (min.)
MTBF
Pd
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com