Total Power International, Inc.
UNIVERSAL INPUT AC-DC EXTERNAL DESKTOP
SWITCHING ADAPTER 42 WATTS GREEN POWER SINGLE
OUTPUT TPEG42 SERIES
FEATURES:
ACCOMMODATE UNIVERSALAC INPUT
DESKTOP IEC320-C14/C6/C8 AC INLET
NO LOAD POWER CONSUMPTION < 0.3W
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN55022 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typical 42-48 Watts.
Output Connector & Cord: Optional.
Line Regulation: Typical 0.5%.
Load Regulation: Typical ±3.0%.
Tolerance: Typical ±5%.
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in, Latch.
Input Voltage: Typical 90-264Vac.
Input Connector: 3 pole AC inlet IEC320-C14(DT7) /
3 pole AC inlet IEC320-C6(DT7L) /
2 pole AC inlet IEC320-C8(DT8).
Input Frequency: 47-63Hz.
Inrush Current: Typical 8.0Arms at 230Vac.
Input Current: Typical 0.63A at 115Vac, 0.35A at 230Vac.
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: Typical 15.6mS at 115Vac,
Typical 89.6mS at 230Vac.
Leakage Current: Less than 0.17mA for class II,
Less than 0.4mA for class I.
No Load Power: Typical 0.16W at 132Vac,
Typical 0.26W at 264Vac.
Overload Protection:
Fully protected against output overload or short circuit.
Typical set at 105-140% at 115Vac.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 87-88%. (various with output voltage)
Switching Frequency: Approximate 59-63KHz.
Circuit Topology: Fixed Frequency flyback circuit.
Transient Response: Output voltage returns in less than
1mS following a 25% load change.
Operating Temperature: 0 to +40°C.
Storage Temperature: -20 to +85°C.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic case.
Power Density: Typ. 3.3-3.8Watts / Cubic inch.
Desktop Format.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage indicate the change in output voltage as the load varied from half load to full load(%)
(3) The exact obtainable load regulation depends upon the output cord selected and load current.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com