R
UMW
TPD1E10B06
Description
The TPD1E10B06 is a single-channel ESD TVS
diode in a small 0402 package convenient for space
contrained applications and an industry standard
SOD-523 package. This TVS protection product offers
±30 kV contact ESD, ±30 kV IEC air-gap protection,
and has an ESD clamp circuit with a back-to-back
TVS diode for bipolar or bidirectional signal support.
The 12 pF line capacitance of this ESD protection
diode is suitable for a wide range of applications
supporting data rates up to 400 Mbps.
SOD-523
1
2
Typical applications of this ESD protection product
are circuit protection for audio lines (microphone,
earphone, and speakerphone), SD interfacing, keypad
or other buttons, VBUS pin and ID pin of USB ports,
and general-purpose I/O ports.This ESD clamp is
good for the protection of end equipment like portable
devices, wearables, set-top boxes, electronic point-of-
sale equipment, appliances, and products for building
automation.
X1SO N
Features
■
•
Provides system-level ESD protection for low-
voltage I/O interface
■
•
IEC 61000-4-2 level 4 ESD protection
– ±30 kV contact discharge
Applications
– ±30 kV air-gap discharge
■
•
End equipment:
– Portable devices
– Wearables
– Set-top boxes
– Electronic point of sale (EPOS)
– Appliances
– Building automation
Interfaces:
– Audio lines
■
•
■•
•
■
IEC 61000-4-5 surge: 6 A (8/20 µs)
I/O capacitance 12 pF (typical)
RDYN 0.4 Ω (typical)
■•
■
•
■•
DC breakdown voltage ±6 V (minimum)
Ultralow leakage current 100 nA (maximum)
10-V clamping voltage (maximum at IPP = 1 A)
Industrial temperature range: –40°C to 125°C
Small 0402 footprint
•
■
■
•
■
•
(1 mm × 0.6 mm × 0.5 mm)
– Push-buttons
■
•
– General-purpose input or output (GPIO)
Industry standard SOD-523 package
(0.8 mm × 1.2 mm)
Specifications
Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
MIN
MAX
90
UNIT
W
IEC 61000-4-5 power (tp - 8/20 µs) at 25°C
Peak pulse
IEC 61000-4-5 current (tp - 8/20 µs) at 25°C
6
A
TA
Operating free-air temperature
Storage temperature
-40
125
155
°C
Tstg
–65
°C
(1)Stresses beyond those listed under
Absolute Maximum Rating may cause permanent damage to the device. These are stress
ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated
under Recommended Operating Condition . Exposure to absolute-maximum-rated conditions for extended periods may affect device
reliability.
www.umw-ic.com
1
友台半导体有限公司