Total Power International, Inc.
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HOT-SWAP
CompactPCI QUAD OUTPUT 500 WATTS ACTIVE CURRENT SHARING
SWITCHING POWER SUPPLIES TPAC500P SERIES
FEATURES:
500W 6U X 8HP EUROCARD PACKAGE
MEET IEC 61000-3-2 HARMONIC
CORRECTION
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
HOT-SWAPPABLE
THIRD-WIRE CURRENT SHARING
EMI MEET EN 55022 / CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Input Voltage: Typ. 90-264Vac.
Output Current: See Ratings Chart.
Power Factor Correction: Meet Harmonic Correction
IEC 61000-3-2.Power Factor typ. 0.99.
Output Power: Typ. 500W continuous.
Output Connector: Positronic 47-pin PCIH47M400A1.
Line Regulation: Typ. 0.1%.
Load Regulation: VO1 & VO2 typ. ±0.5%.
VO3 typ. ±1.0%, VO4 typ. ±3.0%.
Noise & Ripple: Typ. 1% peak-peak or 50mV,
whichever is greater.
OVP: Built-in at all outputs.
Adjustability: Available at VO1,2,3 & 4.
Output Trim: Electrical trim available at VO1/2. [ADJ #].
Remote Sensing: Available at VO1,VO2 & VO3.
Hot-Swap: Available.
Input Connector: Positronic 47-pin PCIH47M400A1.
Input Frequency: 47-63Hz.
Inrush Current: ≤ 30.6A(rms) at 230Vac.
Input Current: 5.1A at 115Vac/2.6A at 230Vac.
Dielectric Withstand: Meet IEC 60950-1 regulation.
Transient Protection: MOV withstands transient as
specified by EN 61000-4-4 level 3.
EMI: Meet EN 55022 Class A.
Hold-up Time: 22.4mS at 115Vac, 34mS at 230Vac.
Remote ON/OFF: Available at [INH#] & [EN#] pins.
Power Fail Signal: Available at [FAL#] pin.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
N+1 Redundancy: Installed with internal OR-ing diodes at all
outputs and third-wire current sharing
method for N+1 redundancy operation.
Current Sharing: Third-wire current sharing at VO1,2 & 3.
DC OK Signal: Available for all outputs.
Power OK Signal: Available for all outputs.
Over Current Protection (OCP): Installed at each rail.
Overload Protection (OLP): Fully protected against output
overload or short circuit. Typ. 120-130% max. load.
Consult the factory for special OLP setting.
Thermal Protection (OTP): Installed NTC and thermostat
for thermal sensor at [DEG#] pin.
Leakage Current: Typ. 0.7mA at 230Vac.
GENERAL SPECIFICATION
Efficiency: Typ. 77%.
Switching Frequency: 120K Hz.
Operating Temperature: -30 to +50 °C at full load with
specified air flow. Derates linearly to 50% at +70°C.
Storage Temperature: -30 to +85 °C.
Circuit Topology: Forward circuit.
Transient Response: Peak transient less than 250mV and
returns to within 1% less than 0.5ms for 50% load-change.
Safety Standard: IEC 60950-1 Class I.
Construction: Eurocard 6U X 8HP X 160mm
CompactPCI format. Front Panel with Extractor handle.
Temperature Coefficient: Typ. ±0.04% / °C.
Cooling: At least 800LFM moving air is required to achieve
full rating power 500W in a confined area.
Power Density: 5.0 Watts/ Cubic Inch.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com