TOTAL POWER INT'L
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HOT-SWAP
CompactPCI QUAD OUTPUT 200 WATTS ACTIVE CURRENT SHARING
SWITCHING POWER SUPPLIES TPAC200P SERIES
FEATURES:
ꢀ
ꢀ
ꢀ
200W 3U X 8HP EUROCARD PACKAGE
MEET IEC1000-3-2 HARMONIC CORRECTION
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
HOT-SWAPPABLE
THIRD-WIRE CURRENT SHARING
EMI MEET EN 55022 / FCC CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 200W continuous.
Output Connector: Positronic 47-PIN
Input Voltage: Typ. 90-264Vac.
Power Factor Correction: Meet Harmonic Correction
IEC1000-3-2.Power Factor typ. 0.96-0.98.
Input Connector: Positronic 47-pin PCIH47M400A1.
Input Frequency: 47-63Hz.
PCIH47M400A1 connector.
Inrush Current: Less than 30.6A @ 230Vac.
Input Current: 2.3A @115Vac/1.2A @230Vac.
Dielectric Withstand: Meet IEC950 regulation.
EMI: Meet EN55022 / FCC Class A.
Line Regulation: Typ. 0.1%.
Load Regulation: VO1 & VO2 typ. ±1.0%.
VO3 & VO4 typ. ±2.0%.
Noise & Ripple: Typ. 1% peak to peak or 50mV,
which is greater.
Hold-up Time: 10mS after power fail signal.
Turn-on Delay/Rise Time: 1 Sec./20 mS.
Earth Leakage: Less than 0.5mA @230Vac.
Remote ON/OFF: Available at [INH#] & [EN#] pins.
Power Fail Signal: Available at [FAL#] pin.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
OVP: Built-in at all outputs.
Adjustability: Available at VO1,2&3.
Output Trim: Electrical trim available at VO1&2. [ADJ #].
Remote Sensing: Available at VO1,VO2 & VO3.
Hot-Swap: Available.
N+1 Redundancy: Installed with internal OR-ing diodes at
all outputs for N+1 redundancy operation.
Current Sharing: Third-wire current sharing at VO1,2 & 3.
Overload Protection (OLP): Fully protected against output
overload or short circuit. Typ. set at 130% max. load.
Consult the factory for special OLP setting.
Thermal Protection (OTP): Installed NTC and thermostat.
for thermal sensor at [DEG#] pin.
Leakage Current: Typ. 0.5A.
Power OK Signal: Available at all output.
Over Current Protection (OCP): Installed in each rail.
GENERAL SPECIFICATION
Efficiency: Typ. 76-79 %.
Operating Temperature: 0 to +50 °C at full load with
specified air flow. Derates linearly to 50% at +70°C.
Storage Temperature: -40 to +85 °C.
Temperature Coefficient: Typ. ±0.02% / °C.
Cooling: At least 20cfm (600 lfm) moving air
is required to achieve full rating power 200W
in a confined area.
Switching Frequency: 130K Hz.
Circuit Topology: Forward circuit.
Transient Response: Peak transient less than 100mV and
recovers within 3mS after 25% load-change.
Safety Standard: IEC60950 Class I.
Construction: Eurocard 3U X 8HP X 160mm
CompactPCI format. Front Panel with
either Ordinary handle or Extractor handle.
Power Density: 3.73 Watts/ Cubic Inch.
Remark: All measurements are at nominal input, full load and +25°C unless otherwise specifications.
In application
TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395
ꢀ
Email: sales@total-power.com http://www.total-power.com