APPLICABLE STANDARD ANSI/TIA/EIA-568-B.2.10 CAT6a
Operating
Temperature Range
Storage
Temperature Range
Operating
Humidity Range
Applicable Cable
Note -25 C TO 60 ℃
-25 C TO 60 ℃
Rating
Voltage
Current
125 V AC
1 A
95 % MAX
AWG# 24 ~ AWG# 26
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring Instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
ELECTRIC CHARACTERISTICS
50 m max.
Contact Resistance
100 mA (DC or 1000 Hz AC)
X
X
(Without bulk resistance of cable)
(One example of connector configuration is shown.)
100 V DC.
Insulation Resistance
Voltage Proof
100 M min.
X
X
X
X
500 V AC FOR 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mechanical Operation
200 times insertions and extractions.
1)Contact resistance: 70 m max.
(Without bulk resistance of cable)
2)No damage, crack and looseness,of parts.
1)No electrical discontinuity of 1 s.
2)Contact resistance: 70 m max.
(Without bulk resistance of cable)
3)No damage, crack and looseness,of parts.
X
X
-
-
Vibration
Frequency 10 to 500Hz, single amplitude 0.35 mm,
at 2h, for 3 directions.
NVIRONMENTAL CHARACTERISTICS
Humidity/temperature
Low temperature 25 ℃
High temperature 65 ℃
Cold sub-cycle -10℃
Relative humidity 93 %
Duration 21/each 24 h
1)Contact resistance: 70 m max.
(Without bulk resistance of cable)
2)Insulation resistance:
X
-
1 M min.(at high humidity)
10M min.(at dry)
3)No damage, crack and looseness,of parts.
1)Contact resistance: 70 m max.
(Without bulk resistance of cable)
2) Insulation resistance: 100 M min.
3) No damage, crack and looseness,of parts.
Rapid Change Of Temperature Temperature:
-40 → 15 to 35 → 70 → 15 to 35 C
X
X
-
-
Time:
30 → 2 to 3 → 30 → 2 to 3 min.
Under 5 cycles.
Corrosion Salt Mist
Exposed in 5 salt water spray for 24 h.
1)Contact resistance: 70 m max.
(Without bulk resistance of cable)
2)No heavy corrosion that lose ness function.
Note. The operation temperature includes the temperature rise by current carrying.
Temperature range for a connector unmated.
Use under the condition recommended by a cable manufacture.
COUNT DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
MN.KENJO
KG.OKITA
20220331
20220331
20220331
20220331
MO.SHIMOYAMA
MO.SHIMOYAMA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
ELC-391045-00-00
TM61P-88P
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CODE NO.
CL0222-0900-0-00
FORM HD0011-2-1