EIA / TIA TSB 40 CAT5
APPLICABLE STANDARD
OPERATING
STORAGE TEMPERATURE
RANGE
-55 C TO +85 C
-25 C TO +60 C
2
1
TEMPERATURE RANGE
OPERATING HUMIDITY
RANGE
RATING
VOLTAGE
CURRENT
125 V AC
0.5 A
95 % MAX
APPLICABLE CABLE
-
SPECIFICATIONS
ITEM
CONSTRUCTION
TEST METHOD
REQUIREMENTS
QT AT
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X X
X X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA MAX (DC OR 1000 Hz AC).
230 m MAX.
X X
(AN EXAMPLE OF CONNECTORCONFIGURATION IS SHOW.)
100 V DC.
INSULATION RESISTANCE
100 M MIN.
X X
X X
VOLTAGE PROOF
500 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
(CONTACT TO CONTACT)
NEAR END CROSSTALK
(NEXT)LOSS
MEASURED MINIMUM NEXT LOSS FOR EACH
PAIR COMBINATION AT 100 MHz.
40 dB MIN.
X -
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
200 TIMES INSERTIONS AND EXTRACTIONS.
1)CONTACT RESISTANCE: 250 m MAX.
2)NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
X -
X -
X -
VIBRATION
FREQUENCY 10 TO 55 Hz SINGLE AMPLITUDE 0.75
mm,
1)NO ELECTRICAL DISCONTINUITY OF 5 s.
2)CONTACT RESISTANCE: 250 m MAX.
3)NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
5 min/CYCLE AT 10 CYCLES.
490 m/s2 DURATION OF PULSE 11 ms
AT 3 TIMES FOR 6 DIRECTIONS.
SHOCK
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT,CYCLIC
EXPOSED AT +40 C, 90 TO 95 ℃ , 500 h
1)CONTACT RESISTANCE: 250 m MAX.
2)INSULATION RESISTANCE:
1 M MIN. (AT HIGH HUMIDITY)
10 M MIN. (AT DRY)
X -
3)NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE
1)CONTACT RESISTANCE: 250 m MAX.
2)INSULATION RESISTANCE: 100 M MIN.
3)NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
X -
-55 ± 3 → 5 TO 35 → 85 ± 2 → 5 TO 35 C
TIME
30 TO 35 → 5 MAX → 30 TO 35 → 5 MAX min
UNDER 5 CYCLES.
CORROSION SALT MIST
EXPOSED IN 5 % SALT WATER SPRAY FOR 48 h.
1)CONTACT RESISTANCE: 250 m MAX.
2)NO HEAVY CORROSION.
X -
X -
X -
RESISTANCE TO SOLDERING SOLDER TEMPERATURE, 260 ± 5 C FOR
HEAT
NO DEFORMATION OF CASE AND EXCESSIVE
LOOSENESS OF THE TERMINALS.
IMMERSION, DURATION 5 ± 1 S.
SOLDERABILITY
SOLDERED AT SOLDER TEMPERATURE, 245 ± 5 C
FOR IMMERSION, DURATION 3 S MAX.
MIN. 95 % OF SOLDER IMMERSED AREA
SHALL BE COVERED NEW SOLDER COATING.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
KIM JAEHYEON
CHECKED
TU.TANIGUCHI
RI.TAKAYASU
YH.ENAMI
DATE
1
△
2
DIS-E-00002932
20200403
20110531
20110531
20110531
20110531
REMARK
THE OPERATION TEMPERATURE INCLUDES THE RYSE
BY CURRENT CARRYING.
STORAGE TEMPERATURE RANGE SHOWS STORAGE CONDITION
FOR UNUSED PRODUCTS INCLUDING PACKING MATERIALS.
FOLLOW THE OPERATING TEMPERATURE RANGE FOR STORAGE
CONDITION AFTER MOUNTING.
1
2
APPROVED
CHECKED
DESIGNED
DRAWN
MT.ITANO
Unless otherwise specified, refer to IEC 60512.
MT.ITANO
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-121543-50-01
TM11R-5N2-88(50)
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1 1/1
CL222-3952-5-50
△
FORM HD0011-2-1