APPLICABLE STANDARD
Operating
Storage
-40 C to +105 C(Note 1)
-55 C to +85 C(Note 2)
Temperature Range
Temperature Range
―
―
―
―
―
Rating
Voltage
Current
Applicable Cable
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Marking
According to drawing.
Visually and by measuring instrument.
Confirmed visually.
X
X
X
X
MECHANICAL CHARACTERISTICS
Mechanical Operation
500 times Insertions and extractions.
-
-
X
X
No damage, crack and looseness of parts
No damage, crack and looseness of parts.
Frequency : 10 to 55 Hz, singe amplitude 0.75 mm,
at 2 h, for 3 axial directions.
(refer to an attached figure)
Vibration
-
-
X
X
frequency : 10 to 500 Hz, singe amplitude 0.35 mm,
acceleration 49 m/s2,10 cycles each, 30 cycles in
total, for 3 axial directions.
10 to 500 to 10 Hz for approx 11 min.(1 oct/min)
No damage, crack and looseness of parts.
JIS E 4031 category 1 class B
Vibration
frequency:5~150Hz
(Railway Random Vibration condition m/s2
asd level(m/s2)2/Hz
Test)
7.90
1.857
3 axial directions, 5 h each.
490 m/s2 duration of pulse 11 ms at 3 times in 3 both axial
No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
-
-
X
X
Shock
directions. half-sine wave.
JIS E 4031 category 1 class B
peak acceleration m/s2 nominal time ms
Shock (Railway)
50
30
3 both axial directions, 3 times each.
ENVIRONMENTAL CHARACTERISTICS
No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
-
-
-
-
-
X
X
X
X
X
Rapid Change Of
Temperature -40 → 15 to 35 → 105 → 15 to 35 C
Temperature
time 30 → 2 to 3 → 30 → 2 to 3 min. under 5 cycles.
Exposed at 105 2 C, 96 h.
Heat Resistance
Cold Resistance
Humidity
Combining the applicable connectors.
Exposed at -55 3 C, 96 h.
combining the applicable connectors.
Exposed at 60 2 C, 90 to 95 %, 96 h.
combining the applicable connectors.
Exposed in H2S 0.1 0.02 ppm, SO2 0.5 0.1 ppm,
25 2 C, 75 3 %, 96 h.
No heavy corrosin ruin the function.
No heavy corrosin ruin the function.
Mixed Flowing Gus
combining the applicable connectors.
Exposed in 5 % salt water spray for 48 h.
combining the applicable connectors.
-
X
Corrosion Salt Mist
Note 1)①The product performance is guaranteed only in the temperature adequate people’s activities.
②Include temperature rise caused by current-carrying.
③Specifications for assembled item with applicable housing.
Note 2)Packing materials are not included.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
RI.TAKAYASU
NM.NISHIMATSU
MO.SHIMOYAMA
MO.SHIMOYAMA
16.01.22
16.01.22
16.01.22
16.01.22
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-129138-00-00
TJ-KY-PF
PART NO.
CODE NO.
SPECIFICATION SHEET
0
1/1
HIROSE ELECTRIC CO., LTD.
CL236-3124-0-00
△
FORM HD0011-2-1