REVISION J
TFSDX-XX-XXX-XX-XX.XX-X-XXX
.110 2.79
REF
PTFE CABLE OPTION
-NXX OPTION (END 2)
*-T: PTFE
(ONLY AVAILABLE WITH -D, -DL, -T OR -TL)
(LEAVE BLANK FOR STANDARD PVC INSULATION)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO PIN 2)
No OF POSITIONS
(No OF POS x .050[1.27])
+ .120[2.54] REF
-02 THRU -030 (PER ROW)
-05, -07, -10, -15, -20, -25 & -30
AVAILABLE AS STANDARD
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO PIN N-1)
N (SEE TABLE 2)
-NUX: NOTCH UP, CROSSED
(PIN 1 TO PIN 1)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO PIN N)
02
.153 3.89
REF
C
L
(ALL OTHER SIZES AVAILABLE AS ASO)
WIRE GAUGE (AWG)
-28, -30
COLOR CODE
.240 6.10
REF
.225 5.72
REF
END OPTION
LEAVE BLANK FOR ALL BLACK WIRE,
C: COLOR CODED WIRE, SEE COLOR
SEQUENCE TABLE, SHEET 2
-S: SINGLE END (USE DWLX-09-XX-S-XX.XX-XX)
*
** -SL: SINGLE END WITH FRICTION LOCK
01
N-1 (SEE TABLE 2)
***
(NOT AVAILABLE WITH PTFE OPTION)
(USE DWLX-09-XX-S-XX.XX-XX)(SEE SHEET 2, FIG. 4)
** -D: DOUBLE END (USE DWLX-09-XX-D-XX.XX-XX)
(SEE SHEET 2, FIG. 2)
.375 9.53
REF
.050 1.27
REF
PLATING SPECIFICATION
-H: HEAVY GOLD (USE DWLX-09-XX-X-XX.XX-H)
-G: LIGHT GOLD (USE DWLX-09-XX-X-XX.XX-G)
-GF: FLASH GOLD (USE DWLX-09-XX-X-XX.XX-GF)
** -T: TRANSFER END (USE DWLX-09-XX-T-XX.XX-XX)
(SEE SHEET 2, FIG. 3 AND SHEET 4)
*
***
FIG. 1
** -DL: DOUBLE END WITH FRICTION LOCK
TFSD-XX-D-S
(USE DWLX-09-XX-D-XX.XX-XX)
-S: SINGLE END
"A"
(TFSDX-07-28-XX-XX.XX-S SHOWN)
(SEE SHEET 2, FIG. 5)
*
***
** -TL: TRANSFER END WITH FRICTION LOCK
(USE DWLX-09-XX-T-XX.XX-XX)
(SEE SHEET 2, FIG. 6)
ASSEMBLED LENGTH
.562 14.26
REF
SPECIFY IN INCHES [USE DWLX-09-XX-X-XX.XX-XX]
(SINGLE END: 03.00 INCH [76.2mm] MINIMUM,
DOUBLE END: 03.25 INCH [82.6mm] MINIMUM)
.238 6.05
REF
* NOT RELEASED FOR PRODUCTION
** MUST CHOOSE FROM -NXX OPTIONS
*** ONLY AVAILABLE ON POS 5, 7, & 10 - 30
C1
XX.XX
(SEE NOTE 12)
DWLX-09-XX-XX-S-XX.XX-XX
*
*
NOTES:
SECTION "A"-"A"
"A"
C
1.
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PULLOUT FORCE: 3 LBS [13.3 N].
3. CONTACT MUST BE INSERTED UNTIL
RETENTION FEATURE LOCKS INTO PLACE.
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
C7 4. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING HI-POT TEST AT 300 V.
AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY WITH 1 LABEL-ET.
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
J
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail: info@SAMTEC.com code: 55322
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
.XXX: .005 [.13]
6. PARTS TO BE LAYER PACKAGED.
.XXXX: .0020 [.051]
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
C8
8. SEE DWLT-09-XX-X-XX.XX-XX-XX FOR CRIMP DIMENSIONS.
MATERIAL:
.050[1.27] SOCKET DISCREET CABLE ASSEMBLY
DWG. NO.
9. NOTE DELETED
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
10. END OF DISCRETE WIRE MUST BE IN RANGE AFTER CRIMP.
11. NOTE DELETED.
CABLE INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
TFSDX-XX-XXX-XX-XX.XX-X-XXX
12. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL
BE ±.125[3.18]. FOR OTHER LENGTHS, TOLERANCES SHALL BE ±2%.
SHEET 1 OF 4
BY:
LENNY K
7/18/06
F:\DWG\MISC\MKTG\TFSDX-XX-XXX-XX-XX.XX-X-XXX-MKT.SLDDRW