COUNT
COUNT
CHKD
DESCRIPTION OF REVISIONS
DATE
DESCRIPTION OF REVISIONS
DATE
CHKD
BY
BY
△
△
△
△
APPLICABLE STANDARD
OPERATING TEMPERATURE
RANGE
STORAGE TEMPERATURE
RANGE
-10℃ ~ +50℃(Packed Condition)
-55℃ ~ +85℃
OPERATING OR STORAGE
HUMIDITY RANGE
APPLICABLE
Relative Humidity
90% MAX(NOT DEWED)
RATING
VOLTAGE
CURRENT
30V [AC(rms) / DC]
0.4A [AC(rms) / DC]
FPC (t=0.2±0.03mm)
CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT
CONFIRMED VISUALLY
O
O
O
O
ACCORDING TO DRAWING
MARKING
ELECTRICAL CHARACTERISTICS
CONTACT RESISTANCE
INSULATION RESISTANCE
VOLTAGE PROOF
MATE APPLICABLE FPC/FFC AND APPLY A CURRENT OF
100mΩ MAX.
O
O
O
O
O
O
1mA DC(OR 1,000Hz)
INCLUDING FPC/FFC BULK RESISTANCE(L=8mm)
MATE APPLICABLE FPC/FFC AND APPLY A VOLTAGE OF
DC 100V
500MΩ MIN.
MATE APPLICABLE FPC/FFC AND APPLY A VOLTAGE OF
AC 150V FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MEASURE BY APPLICABLE FPC/FFC(t=0.2)
①HORIZONTAL DIRECTION : 0.25N X n MIN.
②VERTICAL DIRECTION : 0.25N X n MIN.
(n : NUMBER OF CONTACTS)
FPC RETENSION FORCE
O
AT INITIAL CONDITION
-
MECHANICAL OPERATION
VIBRATION
20 TIMES INSERTIONS AND EXTRATIONS
①CONTACT RESISTANCE : 100mΩ MAX
②NO DAMAGE,CRACK AND LOOSENESS OF PARTS
①NO ELECTRICAL DISCONTINUITY OF 1㎲.
②CONTACT RESISTANCE : 100mΩ MAX
③NO DAMAGE,CRACK AND LOOSENESS OF PARTS
O
O
O
-
-
-
FREQUENCY 10 ~ 55 Hz, TOTAL AMPLITUDE 1.5 mm
AT 2h, IN 3 DIRECTIONS
981m/s2 DIRECTION OF PULSE 6ms AT 3 TIMES
IN 3 DIRECTIONS.
SHOCK
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT(STEADY STATE)
EXPOSED AT 40℃, 90~95 %, 96Hr.
①CONTACT RESISTANCE : 100mΩ MAX.
O
O
-
-
RAPID CHAGE OF TEMPERATURE
TEMPERATURE : -55 → 15~35 → +85 → 15~35 ℃
②INSULATION RESISTANCE : 100MΩ MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
TIME :
30 → 2~3 → 30 → 2~3 min.
UNDER 5 CYCLES.
DAMP HEAT, CYCLE
TEMPERATURE -10→+65
HUMIDITY : 90~95%
①CONTACT RESISTANCE : 100mΩ MAX.
②INSULATION RESISTANCE : 100MΩ MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①CONTACT RESISTANCE : 100mΩ MAX
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①CONTACT RESISTANCE : 100mΩ MAX
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
③NO EVIDENCE OF CORROSISON WHICH AFFECTS
TO OPERATION OF CONNECTOR.
O
-
10 CYCLE(240Hr)
DRY HEAT
EXPOSED AT 85℃, 96Hr
EXPOSED AT -55℃, 96Hr
EXPOSED AT 35℃, 5 % SALT WATER SPRAY FOR 48Hr
O
O
-
-
COLD
CORROSION SALT SPRAY
O
O
-
HYDROGEN SULPHIDE
EXPOSED IN 3 PPM FOR 96Hr.
(TEST STANDARD : JEIDA-38)
REFLOW SOLDERING:
-
RESISTANCE TO
①NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
SOLDERING HEAT
PROFILE : 230℃ 60s, 250℃ MAX.
O
O
-
-
②NO DAMAGE OF ELECTRICAL PERFORMANCE
A NEW UNIFORM COATING OF SLODER
SHALL COVER A MINIMUM OF 95% OF
THE SURFACE BEING EMMERSED.
SOLDER ABILITY
SOLDERED AT SOLDER TEMPERATURE,
ꢄꢅꢆ±ꢀ℃ ꢇꢈꢉ IꢊꢊꢂꢉꢁIꢈꢋ ꢌꢍꢉAꢎIꢈꢋ,
ꢀ±0.ꢀ ꢁꢂꢃ
RELEASED
DRAWN
DESIGNED
CHECKED
APPROVED
REMARKS CONDITIONS FOR TESTING
ENG
M.H.LEE
17.09.29
CHO.D.H
17.09.29
SONG.H.C
17.09.29
M.H.LEE
17.09.29
17.09.29
DEPT
UNLESS OTHERWISE SPECIFIED, REFER TO JIS C 5402.
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST O: APPLICABLE TEST
PART NO.
HIROSE KOREA CO.,LTD.
SPECIFICATION SHEET
TF42-**S-0.35SH(800)
CL ****-****-*
CODE NO.(OLD)
DRAWING NO.
CODE NO.
1
SLC4-632416-80
1
F-1-021(Rev.0)