DC/DC Converter
TEN-60WIN Series 60W
Highest power density 60W converter
Ultra wide 4:1 input voltage
%
CB
Scheme
Low input current at no load
Line regulation
Load regulation
0.2% max.
single output models: 0.5%, dual output models 1%
Output voltage adjustment ± 10% by external resistor (single output models)
91% typ.
Models
Order code
Operating temperature –40°C to +85°C (with derating, tba) optional heatsink
Input voltage
Output voltage
Output current max.
I/O isolation voltage
Safety approvals
Casing
1500 VDC (60 sec.)
TEN 60-2410WIN
TEN 60-2411WIN
TEN 60-2412WIN
TEN 60-2413WIN
TEN 60-2415WIN
TEN 60-2422WIN
TEN 60-2423WIN
TEN 60-4810WIN
TEN 60-4811WIN
TEN 60-4812WIN
TEN 60-4813WIN
TEN 60-4815WIN
TEN 60-4822WIN
TEN 60-4823WIN
3.3 VDC
5 VDC
12000mA
12000mA
5000mA
UL/cUL 60950-1, IEC/EN 60950-1 (pending)
shielded metal with insulated baseplate
www.tracopower.com/products/ten60win.pdf
12 VDC
15 VDC
24 VDC
± 12 VDC
± 15 VDC
3.3 VDC
5 VDC
9-36 VDC
4000mA
Full datasheet
2500mA
50.8
(2.0)
± 2500mA
± 2000mA
12000mA
12000mA
5000mA
Pin-Out
Single
4
1
2
Pin
1
Dual
Bottom View
5
6
+Vin(Vcc)
+Vin(Vcc)
-Vin(GND)
3
12 VDC
15 VDC
24 VDC
± 12 VDC
± 15 VDC
2
-Vin(GND)
18-75 VDC
4000mA
(1.8)
2.54 (0.1)
45.72
3
Remote On/Off Remote On/Off
2500mA
4
+Vout
-Vout
Trim
+Vout
Common
-Vout
± 2500mA
± 2000mA
5
6
DC/DC Converter
TEQ-100WIR Series 100W
High power block with excellent thermal convection
Operating temperature -40°C up to +85°C without derating!
Increased shock & vibration resistance
Ultra wide 4:1 input voltage
CB
Scheme
EN 50155 approval for railway applications
%
Line regulation
Load regulation
Output voltage
Conducted EMI
0.2% max.
0.3% max.
Models
Order code
+10% / -20% adjustable by internal potentiometer
Input voltage Output voltage
Output current max.
TEQ 100-2412WIR
TEQ 100-2415WIR
TEQ 100-2416WIR
TEQ 100-2418WIR
TEQ 100-4812WIR
TEQ 100-4815WIR
TEQ 100-4816WIR
TEQ 100-4818WIR
TEQ 100-7212WIR
12 VDC
8.4A
4.2A
3.6A
2.1A
8.4A
4.2A
3.6A
2.1A
8.4A
4.2A
3.6A
2.1A
92% typ.
9-36 VDC
24 VDC
28 VDC
48 VDC
12 VDC
24 VDC
28 VDC
48 VDC
12 VDC
24 VDC
28 VDC
48 VDC
Operating temperature –40°C to +85°C without derating
Thermal protection
I/O isolation voltage
Safety approvals
Full datasheet
shutdown at 115°C
2250 VDC (60 sec.), basic insulation
18-75 VDC
UL/cUL 60950-1, IEC/EN 60950-1, EN 50155 (Railway) - pending
www.tracopower.com/products/teq100wir.pdf
TEQ 100-7215WIR 43-160 VDC
TEQ 100-7216WIR
TEQ 100-7218WIR
Optional DIN-rail mount adapter
www.tracopower.com
9