TOTAL POWER INT.
T60 AC-DC 60W POWER SUPPLY
.LOW COST, HIGH RELIABILITY
.COMPACT SIZE, LIGHT WEIGHT
.105º C OUTPUT CAPACITOR
.100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
T-60A
CH2
T-60B
CH2
T-60C
CH2
MODEL
SPECIFICATION
CH1
CH3
CH1
CH3
CH1
CH3
DC OUTPUT VOLTAGE
5V
±2%
5A
12V
±6%
2.5A
-5V
±6%
0.5A
0-1A
100m
±0.5%
±1%
5V
±2%
5A
12V
±6%
2.5A
-12V
±6%
5V
±2%
5A
15V
±6%
2A
-15V
±6%
OUTPUT V. TOLERANCE
OUTPUT RATED CURRENT
OUTPUT CURRENT RANGE
RIPPLE & NOISE(Vp-p)
LINE REGULATION
0.5A
0.5A
0.5-7A 0.2-3.5A
0.5-7A 0.2-3.5A
0-1A
0.5-7A 0.2-3A
0-1A
100m
±0.5%
±1%
100m
±1%
100m
±0.5%
±1%
100m
±1%
100m
±0.5%
±1%
100m
±0.5%
±1%
100m
±1%
100m
±0.5%
±1%
LOAD REGULATION
RATED OUTPUT POWER
EFFICIENCY
±4%
±4%
±4%
57.5W
61W
62.5W
72%
72%
72%
DC VOLTAGE ADJ.
CH1:+10,-5%
CH1:+10,-5%
CH1:+10,-5%
INPUT VOLTAGE RANGE
AC CURRENT
85~264VAC 47~63Hz ; 120~370VDC
2A/115V 1A/230V
INRUSH CURRENT
COLD START 30A/115V 60A/230V
<1mA/240VAC
LEAKAGE CURRENT
OVERLOAD PROTECTION
OVER VOLTAGE PROTECTION
TEMP. COEFFICIENT
SETUP,RISE,HOLD UP TIME
VIBRATION
105%~150%/115VAC TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY
CH1:5.75~6.75V
±0.03% / º C (0~50º C) ON +5V OUTPUT
800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC
10~500Hz, 2G 3AXES 10min. / 1cycle ( 1 HOUR / EACH AXES )
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms
-10º C~+60º C(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
-20º C~+85º C, 10%~95% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
DIMENSION
159*97*38mm CASE:901
WEIGHT
0.56Kgs
SAFETY STANDARDS
EMC STANDARDS
UL1012, TUV EN60950, IEC950, UL1950 APPROVED
CISPR22(EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION
1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25º C 70% RH. AMBIENT.
NOTE :
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
7.C23,6 MUST BE REMOVED.