Specifications
Model
SWS600L
SWS1000L
Input Voltage range
Inrush Current (115 / 230VAC)
Power Factor
-
A
-
85 - 265VAC (47 - 63Hz) or 120 - 350VDC*
20 / 40
Meets EN61000-3-2 Class A
Input Current (100/200VAC)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
A
-
-
V
-
ms
mA
-
7.1 / 3.6 (3.3V: 5 / 2.5)
12 / 6
<0.02%/°C
>105%, Constant current style
125% -145%
Yes, cycle AC or Remote On/Off to reset
20ms at 115/230VAC
<0.75mA
Leakage Current (max)
Remote Sense
100µA at 115VAC 60Hz(2)
Yes
Parallel Connection
-
Yes
Remote On/Off (CNT)
-
-
-
-
Yes
Yes
Voltage Programming
DC Good & Fan Fail Signal
Auxiliary Output
(1)
Yes, open collector output
12V 0.1A
LED Indicator
-
Green LED = On
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
°C
°C
-
-40°C start up. -20 to 74°C, derating linearly to 50% load above 50°C
-40 to +85°C
20 - 90% RH operating, 10 - 95%RH non operating
Variable speed internal fan
-
Withstand Voltage(One minute)
-
Input to Ground 2kVAC, Input to Output 3kVAC, Input to Ground 2kVAC, Input to Output 4kVAC**,
OutputtoGround500VAC, OutputtoCNT100VAC Output to Ground 500VAC, OutputtoCNT100VAC
>50M at 25C & 70%RH, Output to Ground 500VDC
MIL-STD-810F 514.5 Cat. 4,10
MIL-STD-810F 516.5 Procedure I, VI
EN61000-4-2, -3, -4, -5, -6, -8, -11
UL/CSA/EN 62368-1, UL/CSA/EN 60950-1, UL/CSA/IEC/EN 60601-1 & ANSI/AAMI ES60601-1,
(1000W only), IEC61010-1 (600W only), EN50178, CE Mark
EN55011 / EN55022-B, FCC Class B
Isolation Resistance
Vibration (non operating)
Shock
Immunity
Safety Agency Certification
-
-
-
-
-
Conducted & Radiated EMI
Weight (Typ)
-
g
1600
2300
Size (WxHxD)
MTBF-Telcordia SR-332 issue 3*** hours
Warranty yrs
in
2.4 x 4.72 x 7.48”
1,444,923
2.4 x 5.91 x 9.45”
1,348,293
Three Years
(1) 1-6V program voltage input to adjust output 20-120% (typical) of nominal. See instruction manual for details & models with this feature.
(2) Worst case: <300µA at 264VAC, 63Hz (Normal Condition); <500µA (Single Fault Condition).
*Safety certified for AC input only
**2 x MOPPs (3rd edition 60601)
*** 24V output model, 25°C ambient, full load, 230VAC input