1W DC-DC Unregulated Single Output Converter
SUS01 series
Features :
1000VDC I/O isolation
Internal SMD technology
Built-in EMI filter
Cooling by free air convection
Non-conductive plastic case
Dual in line package
100% burn-in test
Low cost / High reliability
2 years warranty
SELECTION GUIDE
ORDER NO.
SUS01L-05
SUS01M-05
SUS01N-05
SUS01O-05
SUS01L-09
SUS01M-09
SUS01N-09
SUS01O-09
DC OUTPUT VOLTAGE
5V
9V
OUTPUT CURRENT RANGE 0 ~ 200mA
0 ~ 111mA
75%
EFFICIENCY
73%
74%
72%
74%
79%
80%
77%
ORDER NO.
SUS01L-12
SUS01M-12
SUS01N-12
SUS01O-12
SUS01L-15
15V
SUS01M-15
SUS01N-15
SUS01O-15
DC OUTPUT VOLTAGE
12V
0 ~ 67mA
79%
OUTPUT CURRENT RANGE 0 ~ 84mA
82%
83%
83%
EFFICIENCY
78%
82%
83%
83%
SPECIFICATION
RATED POWER
1W
RIPPLE & NOISE (max.) Note.2
100mVp-p
LINE REGULATION
LOAD REGULATION
VOLTAGE ACCURACY
Note.3
Note.4
1.2% for 1% input variation
OUTPUT
8.0%
2.0%
SWITCHING FREQUENCY
VOLTAGE RANGE
50KHz min.
4.5 ~ 5.5V
5V
10.8 ~ 13.2V 21.6 ~ 26.4V 43.2 ~ 52.8V 4.5 ~ 5.5V
10.8 ~ 13.2V 21.6 ~ 26.4V
43.2 ~ 52.8V
48V
12V
24V
48V
5V
12V
24V
NORMAL VOLTAGE
Full load 280mA
No load 21mA
Capacitor type
112mA
11mA
55mA
10mA
28mA
3mA
280mA
21mA
112mA
11mA
55mA
10mA
28mA
INPUT CURRENT
INPUT
3mA
FILTER
Fuse recommended
Momentary
PROTECTION
OVERLOAD
Protection type : Broken
Momentary
PROTECTION
ENVIRONMENT
SHORT CIRCUIT
Protection type : Broken
-25 ~ +71 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-25 ~ +105 , 10 ~ 95% RH
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
WITHSTAND VOLTAGE
I/P-O/P:1KVDC
SAFETY &
EMC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
80pF max.
ISOLATION RESISTANCE
ISOLATION CAPACITANCE
MTBF
700khrs min. MIL-HDBK-217F(25
)
OTHERS
DIMENSION
22.6*9.9*8.4mm or 0.89"*0.39"*0.33" inch (L*W*H)
3.1g
WEIGHT
Pin Configuration
Derating Curve
Mechanical Specification
Unit: mm (inch)
3.81 (0.15)
9.9 (0.39)
16
0.5 (0.02)
Output
+Vin
Pin No.
1 & 16
6 & 11
7 & 10
8 & 9
100
80
1
-Vout
+Vout
BOTTOM
VIEW
11
10
9
6
7
8
-Vin
2.54 (0.10)
7.62 (0.30)
8.4 (0.33)
-25
0
25
50 60 71
100
Ta (
)
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
NOTE
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 20% to 100% rated load.
File Name: SUS01-SPEC 2011-04-25