General Purpose Relays
Safety Relay SR6
I
6 pole safety relay with either
4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts
Forcibly guided contacts according to EN50205
Rated current 8 A
I
I
I
I
coil power 800 mW or 1200 mW
RoHS compliant (Directive 2002/95/EC)
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-DS
Approvals (in preperation)
V
REG.-Nr. 128935,
Z
E214024,
T
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 3 NC contacts
4 NO contacts and 2 NC contacts
5 NO contacts and 1 NC contact
single contact, forcibly guided
type A according to EN 50205
micro disconnection
8 A
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Contact material
240 / 400 VAC
2000 VA
800 mW version
1200 mW version
AgSnO2 + 0,2 μm Au
AgSnO2
Minimum contact load
Contact resistance
10 mA / 5 V
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
10x106 cycles
Mechanical endurance
Rated frequency of operation with / without load
6 min-1 / 150 min-1
Contact ratings
Type
Load
Cycles
SR6 NO contact
SR6 NC contact
SR6 NO contact
SR6 NO contact
8A, 250VAC, resistiv, 70°C, EN61810-1
8A, 250VAC, resistiv, 70°C, EN61810-1
5A, 250VAC, AC15, 70°C, EN60947-5-1
5A, 24VDC, DC13, 25°C, EN60947-5-1
50x103
20x103
50x103
45x103
Coil data
800 mW
1200 mW
Rated coil voltage range DC coil
Coil power DC coil
5...110 VDC
appr. 800 mW
appr. 1200 mW
Operative range
Coil versions, 800 mW, DC-coil
Coil code
Order. code voltage
2
Nominal
Pull-in
voltage
VDC
3.8
Release
voltage
VDC
0.5
Coil
resistance
c
Rated coil
power
mW
block 4
K05
K06
K09
K12
K18
K21
K24
K36
K40
K48
K60
K85
L10
VDC
5
6
9
12
18
21
24
36
40
48
60
85
110
31+10%
45+10%
806
4.5
0.6
800
6.8
9.0
0.9
101+10%
180+10%
405+10%
551+10%
720+10%
1620+10%
2000+10%
2880+10%
4500+10%
9031+10%
15130+10%
802
1.2
800
13.5
15.8
18.0
27.0
30.0
36.0
45.0
63.8
82.5
1.8
800
2.1
800
2.4
800
3.6
800
4.0
800
4.8
800
6.0
800
8.5
800
11.0
800
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. FC1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2006/03
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.