General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR6 A/B/C/V
n
n
6 pole relay with force guided contacts according to EN 50205
Reinforced insulation between all contacts
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0206-EA
V Z T
Approvals
Coil Data
Coil voltage range
Max. coil power
VDE 128935, UL E214024, TUV 968/EL 350, CQC 0617015576/77
Technical data of approved types on request
5 to 110VDC
1200mW or 800mW
Contact Data
Coil versions, DC-coil 800mW
Contact arrangement
3 form A + 3 form B contacts
3 NO + 3 NC,
4 form A + 2 form B contacts
4 NO + 2 NC,
5 form A + 1 form B contacts
5 NO + 1 NC
Coil
code
Rated
voltage
VDC
12
15
18
21
24
36
Operate
voltage
VDC
9
11.3
13.5
16
Release
Coil
resistance
Ω 10ꢀ
180
Rated coil
power
mW
voltage
VDC
0.9
1.5
1.8
2.1
2.4
3.6
K12
K15
K18
K21
K24
K36
800
801
800
800
800
800
281
405
551
720
Rated voltage
Max. switching voltage
Rated current
250VAC
400VAC
8A
AgSnO2,
18
27
1620
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Contact material
AgSnO2 + 0.2μm Au
single contact, force guided
type A according to EN 50205
5V, 10mA
Contact style
Min. recommended contact load
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
Contact ratings, IEC60947-5-1,
on 2 form A (NO) contact
6/150min-1
AC15-5A
DC13-6A
Mechanical endurance
10x106 operations
Coil versions, DC-coil 1200mW
Coil
code
Rated
voltage
VDC
5
Operate
voltage
VDC
3.8
Release
voltage
VDC
0.5
0.6
0.9
1.2
1.8
2.1
2.4
3.6
4.0
4.8
6
Coil
resistance
Ω 10ꢀ1)
21
Rated coil
power
mW
005
006
009
012
018
021
024
036
040
048
060
110
1190
1200
1191
1200
1200
1198
1200
1200
1200
1200
1200
1200
6
9
4.5
6.8
30
68
120
270
368
480
1080
1333
1920
30001)
100801)
12
18
21
9
13.5
16
24
36
18
27
40
48
30
36
60
110
45
83
11
1) Coil resistance 12ꢀ.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
1
05-2011, Rev. 0511
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.