TM Broadband TelCom Power, Inc.
Redefining “Current” Limits In Power Conversion
BTCPower
Technical Specification
SQ100-48-3.3, SQ100-48-3.3N
48Vin 3.3Vout 25A
SQO100-48-3.3, SQO100-48-3.3N
Description
The SQ(Enclosure)/SQO(Open Frame) family of high power
density, high efficiency DC/DC converters deliver up to 25A
in an industry standard quarter brick footprint. They are
targeted specifically at the telecommunication, industrial
electronics, mobile telecommunication and distributed power
markets. With a wide input voltage range of 36-75V they are
available with output voltages of either 1.5, 1.8, 2.5, 3.3 or 5
Volts. All models feature an input filter, input undervoltage
lockout, output overvoltage and overtemperature protection,
output current limiting and short circuit protection. These
converters are available either in a package that is fully
enclosed with a six-sided metal shield or an alternative,
open-frame construction. In both cases the aluminum heat
spreader design achieves very efficient heat transfer with no
hot spots. The use of patented Flat Transformer technology
and other patented design concepts facilitate very low
temperature rise. The use of highly derated power devices
help to achieve high reliability, high performance and offer a
low cost solution to sys tems designers requiring maximum
power in small footprints.
Features
• Delivers up to 25A in a quarter brick
• High power density up to 90W/inch3
• High efficiency Synchronous topology
• Unique Flat Transformer Technology
• No airflow or heat sink required
• No minImum load required
• Low profile of only 0.34 inch
• 1.5V, 1.8V, 2.5V, 3.3V or 5V output models
• Wide input operating range 36-75V
• -40°C to +100°C ambient operation
• Input undervoltage lockout
• Output overvoltage protection
• Output current limit and short circuit protection
• Remote On/Off pin (Negative logic
also available)
• Output adjustment +/-10% range
• Output remote sense feature
Applications
• 1500V, 10M input-to-output isolation
• Enclosed construction with heat spreader for low
temperature rise
• Telecommunications
• Data Communications
• Also available in an open-frame construction
• Wireless Communications
• Networking Gear
• UL 60950 recognized, TUV EN60950 and CSA C22.2
No. 60950-00 Certified and CE marked
• Servers, Switches and Data Storage
• Semiconductor Test Equipment
• Distributed Power Architecture
• Meets conducted limits of FCC Class B and CEI
IEC61204-3 Class B with external filter
• MTBF of 750,000 hours @ 50°C
(MIL-HDBK-217F)
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A.
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-3.3, SQO100-48-3.3 Rev1 4-2-03