SPU130 SERIES
130W Desk Top (or Mounting Tab) Switching Power Supplies For I.T.E. ( PFC )
Description:
The SPU130 series of AC/DC switching mode power supplies
provide 130 Watts of continuous output power. All supplies are UL
94V-1 min compliant, include IEC-320-C14 input for worldwide
applications. All models meet FCC Part-15 class B and CISPR-22
class B emission Limits and are designed to comply with UL/c-
UL(UL 60950-1) , ITS/GS(EN 60950) and new CE requirements.
All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 3 VDC Thru 55 VDC
Optional Output Connector (See appendix)
Single and Dual Output
Input Surge Current, Over Voltage and Over Load protection
Power Factor Correction(PFC)
Option : Mounting Tab and Desk Top
Long Hold Up Times (75ms)
Class I Insulation
Safety Approvals :
Include a cooling fan
Two years warranty
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
47
264
63
VAC
Hz
Fin Input Frequency
PFC Power Factor Correction
Io=Full load, Vin=230 VAC
Vin=90 to 264VAC
0.95
0
0.99
130
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
W
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
3.2
1.7
A
A
Io=Full load, 25°c ,Cool start,
Irl Low Line Inrush Current
15
30
A
Vin=115VAC
Io=Full load, 25°c, Cool start,
Irh High Line Inrush Current
30
60
85
1
A
Vin=230VAC
Eff Efficiency
Io=Full Load, Vin=230VAC
Io=Full Load
80
0.5
3
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Transient Response
Thold Hold-Up Time
Vin=230VAC
7
%
112
110
132
150
4
%
%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
mS
mS
S
75
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3 1
2
2
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
Tc Temperature Coefficient All output
1
%
0.5 0.75
0.04
mA
%/°c
-0.04
Environmental :
Sym.
Typ.
Max.
Test Conditions
Parameter
Unit
Min.
Toper Operating Temperature
70
85
95
0
-40
5
C
C
%
Tstg
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40 C to 50% load at 70 C
Hr
Pd