SP30U
30 WATT , Universal Input
Fully Enclosed Switching Power Supply
ELECTRICAL SPECIFICATIONS
All specifications are typical at nominal input, full load.
INPUT SPECIFICATIONS
Input Voltage.............................................. AC 85V-264V
DC 110V-340V
Input Frequency.......................................... 47 ~ 63 Hz
Input Current.............................................. 0.33 ~ 0.7A
Inrush Current (100/230VAC cold start) .................13 ~ 35A
OUTPUT SPECIFICATIONS
Output Voltage........................................... See Chart
Output Adjustment.................................... ± 10%
Efficiency.................................................... 70 ~ 79%
Over-Voltage Protection.............................. Zener Limiter
Over-Current Protection.............................. Automatic Recovery (105% min)
FEATURES
Ripple and Noise........................................ 150 mVp-p max.
Hold-Up Time............................................. 20-180 mS
UNIVERSAL INPUT (AC85-264V)
Line/Load Regulation.................................. See Chart
Rise Time.................................................... 100 mS max.
Leakage Current (100/230VAC)........................ Vin= 100V
Vin= 230V
BUILT-IN OVERVOLTAGE / OVERCURRENT
PROTECTION
0.5mA max.
0.75mA max.
LIGHTWEIGHT CONSTRUCTION
METAL CHASSIS WITH COVER
COMPACT, LOW-PROFILE PACKAGES
3 YEAR WARRANTY
GENERAL SPECIFICATIONS
MTBF .......................................................... >245,000 Hours
Isolation Voltage
Primary to Secondary............... 3000VAC
Primary to Case........................ 1500VAC.
Secondary to Case.................... 500VAC.
Isolation Resistance.................................... 100-Mohms min.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature .............................. 0˚-60˚C
Derates linearly 2.5%/˚C after 50˚C
Cooling........................................................ Convection
Temperature Coefficient.............................. 0.02% / ˚C
Humidity.......................................................20-85% Rh (non-condensing)
Storage Temperature.................................. -20˚C + 85˚C
Shock Vibration........................................... Shock: 20G (3 directions each 3 times)
Vibration: 10 ~ 55Hz
SAFETIES / EMI
FCC-B
EN 55022-B
VCCI-II
TUV
PHYSICAL SPECIFICATIONS
Metal Enclosed - Terminal Block
66