RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
■
■
■
RSG
■
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de
ELECTRONIC COMPONENTS
Änderungen vorbehalten / subject to change without notice
750W Single Output Power Supply
SP-750 series
Features :
Universal AC input/Full range
AC input active surge current limiting
Built-in active PFC function,PF>0.96
Protections:Short circuit, overload, over voltage, over temperature
Forced air cooling by built-in DC ball bearing fan
High power density 5.48/inch3
Built-in constant current limiting circuit
With power good and fail signal output
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
SP-750-5
SP-750-12
SP-750-15
SP-750-24
SP-750-27
SP-750-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
120A
62.5A
50A
31.3A
27.8A
15.7A
0 ~ 120A
600W
0 ~ 62.5A
750W
0 ~ 50A
0 ~ 31.3A
751.2W
120mVp-p
22 ~ 26.4V
1.0%
0 ~ 27.8A
750.6W
120mVp-p
24 ~ 30V
1.0%
0 ~ 15.7A
753.6W
120mVp-p
43 ~ 56V
1.0%
750W
120mVp-p
4.75 ~ 5.5V
2.0%
120mVp-p
10 ~ 13.5V
1.0%
120mVp-p
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
13.5 ~ 16.5V
1.0%
VOLTAGE TOLERANCE Note.3
LINE REGULATION
0.5%
0.3%
0.3%
0.5%
0.2%
0.2%
0.2%
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
2.0%
0.5%
0.5%
0.5%
0.5%
1500ms, 50ms/230VAC
1500ms, 50ms/115VAC at full load
16ms/230VAC
16ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
90 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
PF>0.96/230VAC
81%
PF>0.99/115VAC at full load
INPUT
EFFICIENCY (Typ.)
85%
87%
89%
89%
90%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
8.8A/115VAC
27A/115VAC
<2.0mA / 240VAC
4.2A/230VAC
45A/230VAC
105 ~ 125% rated output power
Protection type : Constant current limiting, unit will Hiccup after 3 sec.
5.75 ~ 6.3V
Protection type : Shut down o/p voltage, re-power on to recover
85 (TSW1 ) Detect on heatsink of power transistor 85
OVER LOAD
13.8 ~ 16.2V
18 ~ 21V
27.6 ~ 32.4V
31 ~ 36.5V
57.6 ~ 67.2V
OVER VOLTAGE
OVER TEMPERATURE
PROTECTION
5
5
(TSW2 ) Detect on heatsink of power diode
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
50ms/1ms
POWER GOOD/FAIL
REMOTE CONTROL Note.5
WORKING TEMP.
FUNCTION
RC+/RC- short power on, open power off
-20 ~ +60 (Refer to output load derating curve)
20~90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.05%/ (0 ~ 50
)
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
SAFETY &
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMC
(Note 4)
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, EN61204-3 Heavy industry level, criteria A
769.3K hrs min. MIL-HDBK-217F (25
278*127*63.5mm (L*W*H)
)
OTHERS DIMENSION
PACKING
2.9Kg; 6pcs / 18.4Kg / 0.98CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
NOTE
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. The power supply unit will have no output if the shorting connector is not assembled between RC+ & RC-.
File Name:SP-750-SPEC 2006-10-17