Switching Adapter
Rated
120W
SNP-A12 Series
Features:
●ꢀ
External Desktop Adaptor
●ꢀ
●ꢀ
●ꢀ
●ꢀ
With ITE & Medical safety
Built-in active PFC
Efficiency between 84% to 87%
Compatible to Class I safety & EMC
Applications:
●ꢀ
For medical device such as monitors.
95 x 180 x 50 (mm)
●ꢀ
For peak power required system.
General Specifications:
Input voltage ......................................... 90 VAC to 264 VAC
Input frequency ............................................. 47 Hz to 63 Hz
Inrush current (cold start at 25oC)..............< 60A at 230VAC
Efficiency .............................. 84%~87% depends on models
Holdup time ............................................................. > 16 ms
at rated load and 115VAC
Operating temperature ........................................ 0oC to 40oC
Cooling .................................................... free air convection
Storage temperature ..................................... -20oC to +85oC
EMI ................................................................ FCC class "B"
CISPR22 level "B"
Harmonics .......................................... EN61000-3-2 class D
EMS ...................................... EN61000-4-2, -3, -4, -5,-6,-11
Safety ............................................. UL 60950, UL 60601-1
CSA C22.2 No. 60950, CSA 601-1, CUL
Over voltage protection ........................................... latch off
Short circuit protection..................................... auto recovery
Over load protection ........................................ auto recovery
TUV EN60950-1, EN60601-1
Mechanical Specifications:
Notes:
1. Size:
95 x 180 x 50 (mm)
2. Connectors:
AC input : IEC 320 Inlet
DC output : Molex 5557-06 or equivalent
95.0
ꢀ
(3.74")
180.0ꢀ (7.09")
50.0
(1.97")
3. Box Color : Black
4. Packing
DRAWINGꢀ NO.:ꢀA127
Net weight: 920 g approx. / unit
Gross weight: 16 kg approx. / carton, 14 units / carton
Carton size (mm): 531 (L) x 316 (W) x 337 (H)
0.8(0.03)
-Jim-
10 years Warranty (contact Skynet's Distributors for details)
** This data sheet is only for models selection. For business, engineering specification by model must be used.
NOV. 2016
4-1