Rated
Peak
60W
72W
Switching Adapter
SNP-A06 Series
Features:
●ꢀ
IEC320 C8 Input Socket
With ITE & Medical safety
●ꢀ
●ꢀ
●ꢀ
Compatible to Class II safety & EMC
No load input power < 1W
Applications:
●ꢀ
For industrial device.
●ꢀ
For peak power required system.
65 x 135 x 40 (mm)
General Specifications:
Input voltage ......................................... 90 VAC to 264 VAC
Input frequency ............................................. 47 Hz to 63 Hz
Inrush current (cold start at 25oC) .............< 80A at 230VAC
Meet green mode ...................................... < 1W (at no load)
Efficiency .............................. 80%~87% depends on models
Holdup time............................................................... > 10 ms
at rated load and 115VAC
Over load protection ........................................ auto recovery
Operating temperature ........................................ 0oC to 40oC
Cooling .................................................... free air convection
Storage temperature ..................................... -20oC to +85oC
EMI ................................................................ FCC class "B"
CISPR22 level "B"
Harmonics ........................................... EN61000-3-2 class A
EMS ...................................... EN61000-4-2, -3, -4, -5,-6,-11
Safety .................................. UL 60601-1, UL 60950-1(cUL)
TUV EN60950-1
Over voltage protection ........................................... latch off
Short circuit protection..................................... auto recovery
EN60601-1
Mechanical Specifications:
Notes:
1. Size:
135.0
ꢀ
(5.32")
65 x 135 x 40 (mm)
2. Connectors
AC input : IEC 320 C8
DC output : DC power jack
65.0
ꢀ
(2.56")
3. Box Color : Black
40.0
(1.58")
4. Packing
ꢀ
Net weight: 460 g approx. / unit
Gross weight: 15.5 kg approx. / carton, 24 units / carton
Carton size (mm): 516 (L) x 398 (W) x 283 (H)
-Jim-
10 years Warranty (contact Skynet's Distributors for details)
** This data sheet is only for models selection. For business, engineering specification by model must be used.
NOV. 2016
4-1