Ordering information
DC-DC Converters Bus Converter Power Module Value-addedType
SNDH S
50
A
05 -O
5 6
SNDHS50A
1
2
3
4
1Series name
R
2Single output
3Output wattage
4A : DC60-160V
5Output voltage
6Optional
C: with Coating
R: with Remote ON/OFF
Please refer to Instruction
manual 7.
MODEL
SNDHS50A05
50.0
SNDHS50A12
50.4
SNDHS50A15
51.0
SNDHS50A24
50.4
MAX OUTPUT WATTAGE[W]
DC OUTPUT
5V 10A
12V 4.2A
15V 3.4A
24V 2.1A
SPECIFICATIONS
MODEL
SNDHS50A05
DC60 - 160
0.55typ
83.0typ
5
SNDHS50A12
SNDHS50A15
SNDHS50A24
VOLTAGE[V]
*1
*1
INPUT
0.55typ
85.0typ
12
0.55typ
85.0typ
15
0.55typ
85.0typ
24
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
10
4.2
3.4
2.1
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +95C
10max
24max
100max
120max
150max
240max
200max
280max
300max
120max
240max
40max
30max
100max
120max
150max
240max
200max
280max
300max
150max
300max
60max
48max
100max
120max
150max
240max
200max
280max
300max
240max
480max
90max
150max
80max
*2
*2
*2
RIPPLE[mVp-p]
120max
160max
160max
250max
300max
-20 to 0C
0
to 15% Load
*2
*2
*2
0 to +95C
-20 to 0C
OUTPUT
RIPPLE NOISE[mVp-p]
0
to 15% Load
0 to +50C 50max
-20 to +95C 100max
TEMPERATURE REGULATION[mV]
*3
20max
200max (DCIN 110V, Io=100%)
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*4
4.50 - 5.50
5.00 - 5.15
10.80 - 13.20
12.00 - 12.48
13.50 - 16.50
15.00 - 15.60
21.60 - 26.40
24.00 - 24.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V] 6.30 - 7.60
13.90 - 17.55
17.25 - 21.75
27.60 - 34.80
REMOTE SENSING
REMOTE ON/OFF (RC)
INPUT-OUTPUT, RC
INPUT-FG
None
Optional (Required external power source)
SNDHS
*
5
AC3,000V 1minute, Cutoff current = 15mA, DC500V 50MWmin (20±15C)
AC2,000V 1minute, Cutoff current = 15mA, DC500V 50MWmin (20±15C)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (20±15C)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (20±15C)
ISOLATION
*5
*5
*6
OUTPUT, RC-FG
OUTPUT-RC
-20 to +95C(Aluminum base plate of the power module), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
SAFETY
OTHERS
CONDUCTED NOISE (at only DC input) Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A
CASE SIZE/WEIGHT
COOLING METHOD
61.5X44.5X150mm [2.42X1.75X5.91 inches] (WXHXD) / 270g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC110V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with capacitor of 22mF at 150mm [5.91 inches] from output terminal.
Refer to the instruction manual 3.2.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Refer to the instruction manual 4.6.
*5 Applicable when remote control (optional) is added.
*6 Refer to the instruction manual 6.2.
August11, 2015