LTC Batteries
SL-350 Size: 1AA
› Standard use and stand-by
Performance Data
(Typical values for batteries stored at +25°C for one year)
Typical Discharge Curves at +25 °C
4.0
3.5
3.0
System
Lithium Thionyl Chloride
Nominal voltage
Nominal capacity
Nominal current
3.6 V
1
2
3
4
5
6
7
ꢀ.2 Ah
0.6 mA
2.5
2.0
1.5
1.0
0.5
0.0
1: 560 Ω
2: 1.8 kΩ
~6 mA 0.90 Ah
~2 mA 1.10 Ah
Max. continuous discharge current 6 mA
Anode surface area
Lithium content
Weight
6 cm2
3: 5.6 kΩ ~0.6 mA 1.20 Ah
4: 18 kΩ ~0.2 mA 1.15 Ah
5: 56 kΩ ~0.06 mA 1.05 Ah
6: 180 kΩ ~0.02 mA 0.95 Ah
7: 560 kΩ ~0.006 mA 0.85 Ah
0.35 g
9.6 g
4 cm3
Volume
Temperature range
−55°C ... +85°C
0.1
1
10
102
103
104
105
Time / h
Available Capacity
1.2
1.0
0.8
0.6
0.4
0.2
0.0
4
3
2
SL-350/S
SL-350/T
5
1
+0.2
Ø 4.2−0.3
1: +72 °C
2: +55 °C
3: +25 °C
0
0
4:
0 °C
5: −30 °C
0.5
7
0.01
0.1
1
10
100
1000
Current / mA
3.17
0.15 thick
Operating Voltage
Ø 14.7–1.2
SL-350/P
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
5
4
3
2
45
45
1
6 mA
2 mA
0.6 mA
0.2 mA
0.02 mA
1:
2:
3:
4:
5:
SL-350/PR
SL-350/PT
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
1–0.1
1–0.1
10.16
0.2 thick
0.2 thick
Available Terminations
Catalogue No.
SL-350/S
SL-350/T
SL-350/P
SL-350/PR
SL-350/PT
Standard
ꢀꢀ ꢀ 0350ꢀ 00
ꢀꢀ ꢀ 03502 00
ꢀꢀ ꢀ 03503 00
ꢀꢀ ꢀ 03506 00
ꢀꢀ ꢀ 03508 00
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
Tags
Pins
Pins radial
Polarized tags
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
6
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de