SKS B1 090 GD 69/11 - MA PB
Absolute maximum ratings 1)
Symbol
IOUT MAX
IIN MAX
Conditions
Values
900
Unit
ARMS
ADC
Maximum permanent output current
Maximum permanent input current
Maximum output voltage
Maximum DC Bus voltage
Inverter output frequency
Maximum switching frequency
1 800
760
VAC
VOUT MAX
VBUS MAX
FOUT MAX
FSW MAX
VDC
1 200
100
Hz
5
kHz
T
AMBIENT=40°C unless otherwise specified
Electrical characteristics: application example
Symbol
AC phase
VBUS
Conditions
min
620
-1
typ
max
760
1
Unit
VDC
ARMS
VAC
kW
kHz
Hz
DC bus rated voltage
Rated output current
Output voltage
1 100
900
690
1 080
2
IOUT RATED
VOUT
TINLET=45°C, 50% glycol, No
overload,
liquid flowrate = 16 L/min
POUT
Rated output power
Inverter switching frequency
Output frequency
SKiiP stack
FSW
TJ<150°C,
ambient air temperature = 40°C,
air extraction according to thermal
data page 2
FOUT
50
PF
Power factor
-
2)
Losses at rated current
Efficiency at rated current
SEMISTACK® Renewable Energy - Size W1
10 900
99
W
PLOSS INV
2)
η
%
Two Quadrant 3-phase IGBT inverter
DC Bus
VBUS
VDC
VDC
min
mF
kh
Rated DC voltage applied to the capacitor bank
Max DC voltage applied to the caps bank (max 30% of LTE)
Discharge time of the capacitors (VDC < 60 V)
Capacitor bank capacity
1 100
VBUS MAX
τd5%
1 200
Ordering No. 08800136
5
Description SKS B1 090 GD 69/11 - MA PB
CDC
7,6
100
Features
LTE
Calculated LTE of the caps with forced air cooling
Stack Insulation
ó Designed in regard to EN50178
and UL508C recommendations
ó Designed for a 600 x 600 x 2000 mm cabinet
ó Embedded SKiiP® Technology 3
ó SKiiP 1513GB172-3DW, Trench 3 1700V IGBT,
CAL3 diode
Crd
Minimum creepage distance
11
9.4
mm
mm
Cld
Minimum clearance distance
VDC
Visol
dv/dt
Chassis / power stage AC/DC (insulation test voltage DC, 5s)
SKiiP driver only, secondary to primary side
-4 200
4 200
75
kV/µs
ó Integrated current and temperature sensors
ó Water cooling
Typical Applications
ó Wind generators (SG and DFIG)
ó Solar Inverters
Footnotes
1) Absolute maximum ratings are values not to be
exceeded in any case and do not imply that the stack
can operate in all these conditions taken together.
2) fan consumption and losses in air included
REMARKS
This technical information specifies semiconductor devices but
promises no characteristics. No warranty or guarantee,
expressed or implied is made regarding delivery, performance
or suitability.
B6CI
Rev. 2 - 15.04.2013
© by SEMIKRON
1