Absolute Maximum Ratings
Symbol Conditions
Values
Unit
Power Supply 1)
Vs
19.2 ... 28.8
15 + 0.3
-40 ... 85
-40 ... 85
V
V
°C
°C
ViH
Top
Tstg
Input signal voltage
Operating temperature 2)
Storage temperature
Characteristics
Symbol Conditions
min.
typ.
max.
28.8
Unit
Vs
IS0
Is
VIT+
VIT-
RIN
CIN
supply voltage non stabilized
19.2
24
72
= 72 + 3 *
V
mA
mA
V
V
k
nF
Parallel Board for SKiiP3
SKiiP3 Parallel Board 3-fold
Features
Supply current (no load) 3)
Supply current primary side
Input treshold voltage (HIGH)
Input threshold voltage (LOW)
Input resistance
Is(SKiiP)
4.6
12.3
10
1
Input capacitance
Input-output turn-on signal propagation
time
Input-output turn-off signal propagation
time
short pulse suppression time
Error input-output propagation time
Error memory reset time
Top-Bot interlock dead time
Weight
ꢀ Driving 3 SKiiP in parallel for higher
load current
td(on)IO
td(off)IO
1
1
µs
µs
ꢀ The controller drives 3 SKiiP3
subsystems through one interface
ꢀ Short pulse suppression and extension
ꢀ Generation of dominant dead time for
all paralleled SKiiP3
tSIS
0.625
9
0.009
4
µs
µs
ms
µs
g
td(err)
tpRESET
tTD
ꢀ F-Option board can be easily mounted
ꢀ Detection and handling of error signals
from paralleled SKiiP3
w
105
ꢀ Handling of analogue signals from
paralleled SKiiP3
Mean Time Between Failure @ Ta =
40°C, max. load
MTBF
0.83
106h
ꢀ Monitoring of internal generated supply
voltages
180x93
x27
HxWxD
Dimensions
mm
ꢀ Can be mounted using M4 metal
screws
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1,
Chapter IX
ꢀ Coated with varnish
ꢀ Climate class acc. to IEC60721-3-3:
3K3
* The specifications of our components may not be considered as an assurance of component
characteristics. Components have to be tested for the respective application. Adjustments may
be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly
recommend prior consultation of our staff.
ꢀ Protection level acc. to IEC 60529:
IP00
Typical Applications*
ꢀ Paralleling of 3 GB type SKiiP3
ꢀ Using one controller for driving all
paralleled SKiiP3
Footnotes
1) Supply voltage for connected SKiiP subsystems
2) Operation temperature is real ambient
temperature around the board. Please note: by
longterm operation near upper limit of temperature
the life time decreases.
3) Current consumption of parallel board without
SKiiP subsystems
© by SEMIKRON
Rev. 0 – 15.11.2012
1