100W Open Frame Power Supply for Industrial Equipment
SIFA100 SERIES
–
–
–
–
–
–
–
–
–
–
–
Wide Input Voltage 90 to 260 VAC, 47 to 63Hz
Single Output
Output voltage available from 3 to 50 VDC
Input Surge Current and Overload protection
Over Voltage Protection (Crowbar Design)
Class I Insulation
Operating temperature -20~70°C
Active Power Factor Correction
Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal
Output connector mates with Molex housing 09-50-3131 and Molex 2478 series crimp terminal
Size: 3"x5"x1.18"
3 Year Warranty
Approvals:
Single Output
Product Number
SIFA100-S01
SIFA100-S02
SIFA100-S03
SIFA100-S04
SIFA100-S05
SIFA100-S06
SIFA100-S07
SIFA100-S08
SIFA100-S09
SIFA100-S10
SIFA100-S11
Output Voltage
3 - 5 VDC
Output Current
18.00 - 10.80 A
14.00 - 11.66 A
13.33 - 8.88 A
11.11 - 9.09 A
9.09 - 7.69 A
7.69 - 6.25 A
6.25 - 4.76 A
4.76 - 3.70 A
3.70 - 3.03 A
3.03 - 2.50 A
2.50 - 2.00 A
Total Regulation
Maximum Output Power
5%
5%
5%
5%
3%
3%
3%
2%
2%
2%
2%
54W
70W
80W
5 - 6 VDC
6 - 9 VDC
9 - 11 VDC
11 - 13 VDC
13 - 16 VDC
16 - 21 VDC
21 - 27 VDC
27 - 33 VDC
33 - 40 VDC
40 - 50 VDC
100W
100W
100W
100W
100W
100W
100W
100W
Electrical Characteristics
Parameter
Input Voltage
Test Conditions
Min.
90
Typ.
Max.
260
63
Unit
VAC
Hz
Operating Voltage
Input Frequency
47
Power Factor Correction
Io = Full load, Vin = 90-260VAC
Vin=90 to 264VAC
0.95
0.91
1.0
Output Power Range
0
100
2.0
1.0
W
A
Input Current (Low Line)
Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
A
Io=Full load, 25°C, Cool start,
Vin=115VAC
Low Line Inrush Current
44
50
A
High Line Inrush Current
Efficiency
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
85
80
0.5
3
100
85
1
A
%
70
Line Regulation
%
Load Regulation
Vin=230VAC
5
%
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
112
110
132
150
4
%
%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
mS
mS
S
16
Start Up Time
0.3
1
2
* Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
0.5
0.4
1
%
Io=Full Load, Vin=240VAC
All output
0.75
0.04
mA
%/°C
-0.04
* Note: The Ripple & Noise which is under 3.3VDC at 2% max