5秒后页面跳转
SFSS-08-30-G-04.00-DR-NDS PDF预览

SFSS-08-30-G-04.00-DR-NDS

更新时间: 2024-11-29 08:48:31
品牌 Logo 应用领域
申泰 - SAMTEC /
页数 文件大小 规格书
4页 503K
描述
Cable Assembly, 30AWG,

SFSS-08-30-G-04.00-DR-NDS 数据手册

 浏览型号SFSS-08-30-G-04.00-DR-NDS的Datasheet PDF文件第2页浏览型号SFSS-08-30-G-04.00-DR-NDS的Datasheet PDF文件第3页浏览型号SFSS-08-30-G-04.00-DR-NDS的Datasheet PDF文件第4页 
SFSSX-XX-XXX-XX-XX.XX-XX-XXX  
REVISION Y  
(No OF POS x .050[1.27]) + .021[0.53] REF  
01  
FEP CABLE OPTION  
-NXX OPTION (END 2)  
(ONLY AVAILABLE WITH -D, -DR)  
-NUS: NOTCH UP, STRAIGHT  
(PIN 1 TO PIN N)  
-T: FEP INSULATION  
LEAVE BLANK FOR STANDARD  
PVC INSULATION  
DO NOT  
SCALE FROM  
THIS PRINT  
(SEE NOTE 11)  
-NDS: NOTCH DOWN, STRAIGHT  
(PIN 1 TO PIN 1)  
-NUX: NOTCH UP  
.200 5.08  
REF  
No OF POSITIONS  
.070 1.78 REF  
.095 2.41 REF  
-02 THRU -50  
(PIN 1 TO PIN N)  
WIRE GAUGE (AWG)  
-NDX: NOTCH DOWN  
(PIN 1 TO PIN 1)  
-28  
-30  
.080 2.03 REF  
FIG 1  
END OPTION  
COLOR CODE:  
-S: SINGLE END  
(END OPTION COMBINATIONS NOT AVAILABLE)  
-S: SINGLE END  
LEAVE BLANK FOR ALL BLACK WIRE  
C: COLOR CODED WIRE, SEE TABLE  
2, SHT 4 (SEE NOTE 10)  
(SFSSX-07-28-X-XX.XX-S SHOWN)  
-D: DOUBLE END  
(MUST CHOOSE FROM -NXX OPTIONS)  
-SR: SINGLE ENDED WITH RETENTION LATCH  
(SEE SHEET 4, FIG 3)  
PLATING SPECIFICATION  
(VALUES GIVEN ARE IN MICRO INCHES)  
ISDF-XX-S  
-H: HEAVY GOLD, 30 Au / 50 Ni MIN ON  
CONTACT, 3 Au / 50 Ni MIN ON TAIL  
-G: GOLD, 10 Au / 50 Ni MIN ON  
(ONLY AVAILABLE ON -02 THRU -50 POS)  
-DR: DOUBLE ENDED WITH RETENTION LATCH  
(SEE SHEET 4, FIG 4)  
.050 1.27 REF  
"A"  
CONTACT, 3 Au / 50 Ni MIN ON TAIL  
-F: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON  
CONTACT, 3 AU / 50 NI MIN ON TAIL  
-GF: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON  
CONTACT, 3 AU / 50 NI MIN ON TAIL  
(ONLY AVAILABLE ON -02 THRU -50 POS)  
(MUST CHOOSE FROM -NXX OPTIONS)  
ASSEMBLED LENGTH  
SPECIFY IN INCHES  
.440 11.18  
REF  
C
**  
(SEE TABLE 2, SHEET 4)  
(SINGLE END: 03.00 INCH [76.2mm]  
MINIMUM,  
.249 6.32  
REF  
**: -GF ONLY AVAILABLE TO  
EXISTING CUSTOMERS  
SEE -F PLATING  
DOUBLE END: 03.25 INCH [82.6mm]  
MINIMUM)  
"A"  
SECTION "A"-"A"  
C
XX.XX  
(SEE NOTE 8)  
C
XX.XX  
(SEE NOTE 8)  
DWCX-XX-XX-300  
(SEE TABLE 1)  
FIG 2  
-D: DOUBLE END  
NOTES:  
1.  
(SFSSX-07-28-X-XX.XX-D-NUS SHOWN)  
C
REPRESENTS A CRITICAL DIMENSION.  
(SAME AS FIG 1, UNLESS OTHERWISE STATED)  
2. MINIMUM PULLOUT FORCE: 3.0 LBS [13.3 N].  
3. CONTACT MUST BE INSERTED UNTIL  
C
C
PROPRIETARY NOTE  
THIS DOCUMENT CONTAINS CONFIDENTIAL AND  
PROPRIETARY INFORMATION AND ALL DESIGN,  
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS  
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,  
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE  
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR  
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY  
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS  
WRITTEN CONSENT OF SAMTEC, INC.  
*
*
UNLESS OTHERWISE SPECIFIED,  
DIMENSIONS ARE IN INCHES.  
TOLERANCES ARE:  
RETENTION FEATURE LOCKS INTO PLACE.  
4. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING  
HI-POT TEST AT 1000 VOLTS DC. AFTER FINAL ELECTRICAL TEST,  
LABEL EACH ASSEMBLY WITH (1) ET STAMP ON THE BODY.  
5. TINNED COPPER WIRE IS RoHS COMPLIANT.  
DECIMALS  
ANGLES  
2
.XX: .01 [.3]  
520 PARK EAST BLVD, NEW ALBANY, IN 47150  
.XXX: .005 [.13]  
PHONE: 812-944-6733  
FAX: 812-948-5047  
code 55322  
6. PARTS TO BE LAYER PACKAGED.  
.XXXX: .0020 [.051]  
e-Mail info@SAMTEC.com  
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.  
8. FOR LENGTHS LESS THAN 12 in, TOLERANCE SHALL BE +/-.125.  
FOR OTHER LENGTHS, TOLERANCE SHALL BE +/-2%.  
SHEET SCALE: 2:1  
DO NOT SCALE DRAWING  
MATERIAL:  
DESCRIPTION:  
INSULATOR: LCP, COLOR: BLACK  
CONTACT: BeCu  
CABLE INSULATION: PVC OR FEP  
.050[1.27] SOCKET DISCRETE CABLE ASSEMBLY  
DWG. NO.  
9. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,  
TOLERANCES, TOOLING, AND ITS REQUIREMENTS.  
WIRE: DWC: TINNED COPPER, DWCT: TIN PLATED COPPER  
(SEE TABLE 1)  
SFSSX-XX-XXX-XX-XX.XX-XX-XXX  
10. COLOR CODED CABLE NOT AVAILABLE WITH SFSST (FEP).  
11. ASSEMBLIES USING THE FEP OPTION ARE FOR CRIMP APPLICATIONS ONLY.  
SHEET 1 OF 4  
BY:  
GAYNOR 6/12/2008  
C:\EnterpriseVault\DWG\MISC\MKTG\SFSSX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW  

与SFSS-08-30-G-04.00-DR-NDS相关器件

型号 品牌 获取价格 描述 数据表
SFSS-08-30-G-06.00-S SAMTEC

获取价格

Board Connector, 8 Contact(s), 1 Row(s), Female, 0.05 inch Pitch, Crimp Terminal, Locking,
SFSS-08-30-GF-03.25-DR SAMTEC

获取价格

Interconnection Device
SFSS-08-30-H-03.25-D SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-F-03.25-D SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-F-03.25-DR SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-G-03.25-D SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-G-03.25-DR SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-H-03.25-D SAMTEC

获取价格

Interconnection Device
SFSS-09-28C-H-03.25-DR SAMTEC

获取价格

Interconnection Device
SFSS-09-28-G-05.00-D-NUS SAMTEC

获取价格

Cable Assembly, 28AWG,