(pending)
POLARISED, MONOSTABLE
SAFETY RELAY
SF-RELAYS
Double contact
FEATURES
25.0
.984
• High contact reliability
• Separated chamber structure (2 Form
A 2 Form B, 4 Form A 4 Form B)
N.O. and N.C. side contacts are put in
each own space surrounded with a card
and a body-separater.That prevents short
circuit between contacts, which is caused
by their springs welding or damaged.
• High breakdown voltage 2,500 Vrms
between contacts and coil
53.3±0.3
2.098±.012
High contact reliability is achieved through
the use of a double contact.
• Forced operation contacts
16.5±0.5
.650±.020
(2 Form A 2 Form B)
N.O. and N.C. side contacts are
connected through a card so that one
interacts with the other in movement. In
case of a contact welding, the other keeps
a min. 0.5mm .020inch contact gap.
• Independent operation contacts
(4 Form A 4 Form B)
There are 4 points of forced operation
contacts.
Each pair of contacts is free from the main
armature and is independent from each
other. So if a N.O. pair of contacts are
welded, the other 3 N.O. contacts are not
effected (operate properly) That enables
to plan a circuit to detect welding or go
back to the beginning condition.
2 Form A 2 Form B
33±0.5
1.299±.020
53.3±0.3
2.098±.012
• High sensitivity
16.5±0.5
.650±.020
Realizes thin shape and high sensitivity
(500 mW nominal operating power) by
utilizing high-efficiency polarized
magnetic circuit with 4-gap balanced
armature.
• Complies with safety standards
Standard products are UL, CSA, TÜV and
SEV certified. Comform to European
standards. TÜV certified (945/EL, 178/
88). Complies with SUVA European
standard.
4 Form A 4 Form B
mm inch
SPECIFICATIONS
Contact
Characteristics
2 Form A
2 Form B
4 Form A
4 Form B
2 Form A
2 Form B
4 Form A
4 Form B
Contact arrangement
Contact arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. operating speed
Initial insulation resistance*1
180 cpm (at nominal voltage)
Min. 1,000 MΩ at 500 V DC
1,300 Vrms
30 mΩ
Contact material
Gold-flashed silver alloy
Between open contacts
Initial
Nominal switching
capacity
breakdown Between contact sets
2,500 Vrms
6 A 250 V AC, 6 A 30 V DC
voltage*2
Between contact and coil
2,500 Vrms
Rating
(resistive)
Max. switching power
1,500 VA, 180 W
Operate time*3 (at nominal voltage)
Release time (without diode)*3
(at nominal voltage)
Approx. 17 ms Approx. 18 ms
Max. switching voltage
440 V AC, 30 V DC
Approx. 7 ms Approx. 6 ms
Max. carrying current
6 A
107
Expected
life (min.
operations)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
Max. 45°C
with nominal coil voltage and
at 6 A carry current
Temperature rise (at nominal voltage)
(at 20°C)
105
Functional*4
Shock resistance
Min. 294 m/s2 {30 G}
Min. 980 m/s2 {100 G}
Coil
Destructive*5
Nominal operating power
500 mW
10 to 55 Hz at double
amplitude of 2 mm
Remarks
Functional*6
Vibration resistance
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
10 to 55 Hz at double
amplitude of 2 mm
Destructive
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Conditions for operation,
Ambient
–40°C to +70°C
–40°F to +158°F
transport and storage*7 (Not temp.
freezing and condensing at
*6 Detection time: 10µs
*7 Refer to 6. Usage, transport and storage mentioned in NOTES
Humidity
5 to 85% R.H.
low temperature)
Approx.
38 g 1.34 oz
Approx.
47 g 1.66 oz
Unit weight
4