SUPER FAST RECOVERY RECTIFIER
VOLTAGE RANGE
CURRENT
50 to 600 Volts
3.0Ampere
SF31 THRU SF38
DO-27
.052(1.3)
.048(1.2)
DIA.
FEATURES
·
·
·
·
·
Low coat construction
Fast switching for high efficency.
Low reverse leakage
High forward surge current capability
High temperature soldering guaranteed:
260℃/10 secods/.375”(9.5mm)lead length at 5 lbs(2.3kg) tension
1.0(25.4)
MIN.
.375(9.5)
.335(8.5)
.220(5.6)
.197(5.0)
DIA.
MECHANICAL DATA
1.0(25.4)
MIN.
·
·
·
·
·
·
Case: Transfer molded plastic
Epoxy: UL94V-O rate flame retardant
Polarity: Color band denotes cathode end
Lead: Plated axial lead, solderable per MIL-STD-202E method 208C
Mounting position: Any
(millimeters)
Dimensions in inches and
Weight: 0.042ounce, 1.19grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
·
·
·
Ratings at 25OC ambient temperature unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load
For capacitive load derate current by 20%
SF
SYMBOLS
31
SF
32
SF
33
SF
34
SF
35
SF
36
SF
37
SF
38
UNITS
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50
35
50
100
70
150
105
150
200
140
200
300
210
300
400
280
400
500
350
500
600 Volts
420 Volts
600 Volts
Maximum DC Blocking Voltage
100
Maximum Average Forward Rectified Current
0.375”(9.5mm) lead length at TA= 55℃
I(AV)
5.0
Amp
Peak Forward Surge Current
8.3mS single half sine wave superimposed on
rated load (JEDEC method)
IFSM
VF
IR
125
Amps
Maximum Instantaneous Forward Voltage @ 3.0A
0.95
1.25
1.7
Volts
TA = 25℃
TA = 125℃
5.0
50
Maximum DC Reverse Current at Rated
DC Blocking Voltage
µA
Maximum Reverse Recovery Time
Test conditions IF=0.5A,IR=1.0A,IRR=0.25A
Typical Thermal Capavitance
trr
CJ
35
ns
PF
50
30
(Measured at 1.0MHz and applied rever voltage of 4.0V)
Typical Thermal Resistance(NOTE 1)
RθJA
TJ
30
℃/W
℃
Operating Junction Temperature Range
Storage Temperature Range
Notes:
(-55 to +150)
(-55 to +150)
℃
TSTG
1. Thermal resistance from junction to ambient with .375”(9.5mm)lead length, PCB. mounted. .
Web Site: