Preliminary
SF2211E
• No Matching Network Required for 50 Ω Operation
• Surface-mount 3.0 x 3.0 mm Package
• Complies with Directive 2002/95/EC (RoHS)
Pb
1200 MHz
SAW Filter
Absolute Maximum Ratings
Rating
Value
10
Units
dBm
V
Input Power Level
DC Voltage on any Non-ground Terminal
Operating Temperature Range
3
-55 to +85
-40 to +85
-55 to +95
260
°C
°C
Storage Temperature Range in Tape and Reel
Component Storage Temperature Range
Solder Reflow Temperature, 10 seconds, 5 cycles maximum
°C
°C
SM3030-6
Electrical Characteristics
Characteristic
Center Frequency
Insertion Loss, 1180 to 1220 MHz
Attenuation, 0 dB Reference:
1080 MHz
Sym
Notes
Min
Typ
1200
2.8
Max
Units
f
MHz
dB
C
IL
4.0
35
45
40
35
60
60
48
52
50
50
1100 MHz
dB
1300 MHz
1320 MHz
Z
Source Impedance
Load Impedance
S
Ω
Z
L
Case Style
SM3030-6 3.0 x 3.0 mm Nominal Footprint
945, YWWS
Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator
Standard Reel Quantity
Reel Size 7 Inch
Reel Size 13 Inch
500 Pieces/Reel
3000 Pieces/Reel
Electrical Connections
Connection
Port 1
Terminals
2
5
1
6
Port 2
Case Ground
All others
5
0
L
o h m
a d
5
S
0 o h m
u r c e
5
2
o
o
4
3
(
b
o
t
t
o
m
v
i
e
w
)
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1.
Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance
matching to 50 Ω and measured with 50 Ω network analyzer.
2.
3.
Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external
impedance matching design. See Application Note No. 42 for details.
4.
5.
6.
"LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
The design, manufacturing process, and specifications of this filter are subject to change.
Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port
2, so that the filter must always be installed in one direction per the circuit design.
US and international patents may apply.
RFM, stylized RFM logo, and RF Monolithics, Inc., are registered trademarks of RF Monolithics, Inc.
7.
8.
www.RFM.com E-mail: info@rfm.com
©2009-2010 by RF Monolithics, Inc.
Page 1 of 5
SF2211E - 7/16/10