SF2143B
• Designed for SDARS IF
• SAW Diplexer 72.54 MHz / 80.46 MHz
• 5.0 X 7.0 mm Surface-mount Case
• Complies with Directive 2002/95/EC (RoHS)
72.54 / 80.46 MHz
SAW Diplexer
Pb
Absolute Maximum Ratings
Rating
Value
+10
Units
dBm
VDC
°C
Maximum Incident Power in Passband
Maximum DC Voltage Between any Two Terminals
Operating Temperature Range
0
-40 to +105
-40 to +85
260
°C
Storage Temperature Range in Tape and Reel
Peak Solder Reflow Temperature, 10 seconds/5 cycles
°C
SMP-03
Electrical Characteristics TDM1 Filter
Characteristic
Nominal Center Frequency
Passband Width:
Sym
fC
BW1
BW15
BW30
ILMIN
Notes
Min
Typ
72.54
4.1
6.4
7.3
16
0.6
42
42
33
33
43
Max
Units
MHz
MHz
MHz
MHz
dB
dBP-P
dB
dB
dB
dB
dB
dB
1 dB
15 dB
30 dB
3.7
1
6.7
7.5
18
Passband Minimum Insertion Loss (including matching network) at fC
Amplitude Ripple, fC ± 1.85 MHz
Attenuation Relative to Minimum Insertion Loss:
1.3
50.00 to 66.48 MHz
66.48 to 68.08 MHz
77.30 to 78.60 MHz
78.60 to 86.50 MHz
86.50 to 91.50 MHz
91.50 to 100.0 MHz
40
37
30
30
39
42
46
Group Delay Ripple
30
150
nsP-P
Source Impedance, Differential
Load Impedance, Differential
27 ohms or 200 ohms
1K ohms or 1.5K ohms
Electrical Characteristics TDM2 Filter
Characteristic
Nominal Center Frequency
Passband Width:
Sym
fC
BW1
BW15
BW30
ILMIN
Notes
Min
Typ
80.46
Max
Units
MHz
MHz
MHz
MHz
dB
dBP-P
dB
dB
1 dB
15 dB
30 dB
3.7
4.2
6.4
7.2
15
0.7
42
38
38
1
6.7
7.5
18
Passband Minimum Insertion Loss (including the matching network) at fC
Amplitude Ripple, fC ± 1.85 MHz
Attenuation Relative to Minimum Insertion Loss:
1.3
50.00 to 74.39 MHz
39
33
30
35
43
74.39 to 75.99 MHz
85.21 to 86.50 MHz
86.50 to 91.50 MHz
91.50 to 100.0 MHz
dB
dB
dB
40
46
Group Delay Ripple
40
150
nsP-P
Source Impedance, Differential
Load Impedance, Differential
27 ohms or 200 ohms
1K ohms or 1.5K ohms
Case Style
SMP-03 7 x 5 mm Nominal Footprint
RFM SF2143B YYWWS
6
Lid Symbolization (YY=year, WW=week, S=shift) See note 4
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1.
Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance matching to
50 Ω and measured with 50 Ω network analyzer.
2.
3.
Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc.
Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external impedance
matching design. See Application Note No. 42 for details.
4.
5.
6.
7.
"LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E" indicates "engineering prototypes."
The design, manufacturing process, and specifications of this filter are subject to change.
Tape and Reel Standard ANSI / EIA 481.
Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port 2, so that
the filter must always be installed in one direction per the circuit design.
US and international patents may apply.
RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of RF Monolithics, Inc.
8.
9.
www.RFM.com E-mail: info@rfm.com
©2009-2010 by RF Monolithics, Inc.
Page 1 of 6
SF2143B - 8/10/10