SF08E60D1
Voltage 600V
8 Amp Super Fast Rectifier
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen free
TO-252
FEATURES
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Fast switching for high efficiency
Low forward voltage drop
High current capability
Low reverse leakage current
High surge current capability
A
C
D
B
MECHANICAL DATA
G E
H F
ꢀ
ꢀ
ꢀ
ꢀ
Case: Molded plastic
Plastic Materials used Carries Underwriters
Laboratory Flammability Classification 94V-O
Lead Temperature for Soldering Purposes:
265℃ Max. for 10 Seconds
K
J
N
O
P
M
Millimeter
Min. Max.
Millimeter
REF.
REF.
Min.
Max.
A
B
C
D
E
F
6.35
4.95
2.10
0.43
6.0
2.80 REF
5.40
0.60
6.90
5.50
2.50
0.9
J
K
M
N
O
P
2.30 REF.
PACKAGE INFORMATION
0.64
0.50
1.3
0
1.14
1.14
1.8
Package
TO-252
MPQ
2.5K
Leader Size
13’ inch
7.5
0.13
0.58REF.
G
H
6.40
1.20
Pin 1
Pin 3
Pin 2
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise s pecified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
VRRM
VRSM
VDC
IF
600
600
600
8
V
V
V
A
A
A
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
Peak Repetitive Forward Current
35
IFM
IFSM
29
Peak Forward Surge Current, 8.3 ms single half sine-wave
Typical Thermal Resistance
Rθ
JC
10
°C /W
°C
Operating and Storage Temperature Range
TJ,TSTG
-55~150
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Typ.
Max.
1.7
-
Unit
Test Condition
IF = 8 A, TJ = 25°C
Maximum Instantaneous Forward
Voltage
1.5
1.3
0.002
-
VF
V
IF = 8 A, TJ = 125°C
TJ=25°C
0.2
20
35
-
Maximum DC Reverse Current
at Rated DC Blocking Voltage 3
Max. Reverse Recovery Time 1
Typical Junction Capacitance 2
NOTES:
IR
mA
TJ=100°C
TRR
CJ
22
nS
pF
53
1. Reverse recovery test conditions IF= 0.5A, IR= 1.0A, IRR= 0.25A.
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3. Pulse Test:Pulse Width = 300 µs, Duty Cycle ≦ 2.0%.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
02-Dec-2013 Rev.A
Page 1 of 2