Version:V1.0
SEV60
High Voltage DC Relay
Feature
SANYOURELAYS
Relays for advanced technology
●60 amps continuous carry,600 amps interrupte under
extreme condition.
●Hermetically sealed with hydrogen gas,the arc is not exposed.
Be able to use in explosive & harsh environments without
oxidation or contamination of contacts.Contacts' part meet
IP67 protection degree.
●Not position sensitive- can be mounted in any position for
ease of installation.
●RoHS compliant.
Contact Data
Parameters Table
Item
Information
1 Form A contact
60A
Item
Information
5×105 cycles
Mechanical life
Contact arrangement
Current rating
Insulation resistance
Between
1000MΩ(500VDC)
Contact resistance
≤1.5mΩ(@6V 20A)
3000VAC 1min 10mA
4000VAC 1min 10mA
open contacts
Dielectric
strength
Between
contact and coil
Min.Switching load
Max. Breaking current
Max. Switching power
150VDC
Operate time
(at rated coil voltage)
Release time
(at rated coil voltage)
600A(150VDC,1cycle)
≤30ms
≤10ms
9KW
1×105 cycles,(60A,24VDC)
196m/s2(20G)
490m/s2(50G)
Functional
Shock
resistance
4×104 cycles,(60A,48VDC)
2×104 cycles,(60A,72VDC)
1×104 cycles,(60A,150VDC)
60A:continuity
Destructive
Electrical
life(1)
Resistive
load
10Hz~500Hz 49m/s2(5G)
-40℃~85℃
Vibration resistance
Ambient temperature
Ambient humidity
5%~95% RH
Approx.195g
Weight
90A:1h
120A:20min
240A:30s
360A:1s
Load current
capacity(2)
External dimension
76.6×46×36.85
Coil Data(3)
Rated voltage(VDC)
Operation voltage(VDC)
Max. voltage(VDC)
24
24
12
12
16
32
Pick-up voltage(VDC)
≤18
≤9
NOTES:
Drop-out voltage(VDC)
Coil resistance(±10%)(Ω)
≥1.0
≥2.0
192
3
(1)Ambient temperature:23℃,L/R≤1ms.
(2)Ambient temperature:23℃,15mm2
conductor.
(3)Other types of rated voltage,please
contact us.
48
3
Operating power
(inrush,W)
Operating power
(stable,W)
3
3
1/3