Version:V4.0
High Voltage DC Relay
Feature
SEV1S0E0C系25列0
SANYOURELAYS
Relays for advanced technology
●200 amps continuous carry,2000 amps interrupte under
extreme condition.
●Hermetically sealed with hydrogen gas,the arc is not exposed.
Be able to use in explosive & harsh environments without
oxidation or contamination of contacts.Contacts' part meet
IP67 protection degree.
●Not position sensitive- can be mounted in any position for
ease of installation.
●RoHS compliant.
Contact Data
Parameters Table
Item
Information
Item
Information
Mechanical life
5×105 cycles
Contact
arrangement
Power Contact:1 Form A
Auxiliary Contact:1 Form A
Insulation resistance
Between
1000MΩ(500VDC)
Current rating
Auxiliary road
200A
3300VAC 1min 10mA
Dielectric
strength
open contacts
1A 30VDC/1A 125VAC
≤0.6mΩ(@200A)
12VDC 1A
Between
3300VAC 1min 10mA
≤50ms
Contact resistance
Min.Switching load
contact and coil
Operate time
(at rated coil voltage)
Release time
(at rated coil voltage)
≤50ms
Max. Switching voltage
Max. Breaking current
Max. Switching power
750VDC
196m/s2(20G)
490m/s2(50G)
10Hz~500Hz 49m/s2(5G)
-40℃~85℃
Functional
Shock
2000A(300VDC,1 cycle)
resistance
Destructive
188KW
Vibration resistance
500V type
750V type
Ambient temperature
500VDC,200A
4000cycles
750VDC,200A
1000cycles
Resistive
load
Ambient humidity
Weight
5%~95% RH
Electrical
life(1)
500VDC,250A
1500 cycles
750VDC,250A
500cycles
Approx.445g
2.5×104cycles
22.5VDC,τ=1ms
inrush 400A
2.5×104cycles
37.5VDC,τ=1ms
inrush 400A
External dimension
Capacitive
load
77.8mm×66.5mm×73.3mm
steady 200A
steady 200A
200A:continuity
CoilData(3)
300A:1h
400A:20min
800A:30s
Rated voltage(VDC)
Operation voltage(VDC)
Max. voltage(VDC)
12
12~24
Load current
capacity(2)
36
Pick-up voltage(VDC)
Drop-out voltage(VDC)
≤9
≥1.0
3.4
2000A:0.6s
NOTES:
Coil resistance(±10%)(Ω)
(1)Ambient temperature:23℃,L/R≤1ms.
(2)Ambient temperature:23℃,60mm2
conductor.
(3)Other types of rated voltage,please
contact us.
Operating power
(inrush,W)
Operating power
42
2.6
(stable,W)
1/4