75W Single Output Switching Power Supply
SCP-75 series
Features :
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage / Battery
polarity protections (by fuse)
Cooling by free air convection
LED indicator for power on
No load power consumption <0.75W
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
SCP-75-12
SCP-75-24
DC VOLTAGE
13.8V
5.4A
27.6V
2.7A
RATED CURRENT
CURRENT RANGE
PEAK 5S
0 ~ 5.4A
0 ~ 2.7A
3.2A
Note.6 6.5A
74.5W
RATED POWER
74.5W
200mVp-p
+15,-5%
1.0%
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION Note.4 1.0%
LOAD REGULATION Note.5 2.0%
OUTPUT
+15,-5%
1.0%
1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC
1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
120 ~ 370VDC
0.9A/230VAC
FREQUENCY RANGE
EFFICIENCY (Typ.)
85%
81%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
TEMP. COMPENSATION
1.5A/115VAC
COLD START 45A
<2mA / 240VAC
By NTC (not provide with the power supply)
+0.7
FUNCTION
OUTPUT VOLTAGE SENSOR L=output voltage
V
-0
3.2 ~ 4.3A rated output power
6.5 ~ 8.7A rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
16.6 ~ 19.3V
33.1 ~ 38.6V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45
)
TEMP. COEFFICIENT
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1),CCC GB4943 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 6)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
461.2K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.5Kg; 30pcs/16Kg/1CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. 33% Duty cycle maximum within every 15 seconds. Average output power should not exceed the rated power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCP-75-SPEC 2010-02-09