SCp-1k2 series
900~1200W Parallel Type With PFC Function
ꢏꢗꢡꢍꢌꢕꢗꢙꢁꢚ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢄꢈ�ꢀꢁꢉꢊꢋꢌꢍ
ꢎꢏꢐꢄꢑꢒꢃꢓꢁꢆꢔꢄꢈ�ꢀ
ꢎꢕꢖꢍꢗꢘꢍꢉꢖꢊꢙꢚꢁꢛꢜꢖꢕꢍꢁꢘꢉꢕꢘꢌꢉꢍꢝꢁꢞꢟꢗꢕꢠꢖꢡꢢꢝꢁꢞꢟꢗꢕꢁꢟꢖꢠꢍꢡꢣꢗꢝꢁꢞꢟꢗꢕꢁꢍꢗꢤꢋꢗꢕꢡꢍꢌꢕꢗ
ꢥꢌꢉꢠꢍꢁꢉꢊꢁꢕꢗꢤꢖꢍꢗꢁꢙꢗꢊꢙꢗꢁꢦꢌꢊꢘꢍꢉꢖꢊ
ꢥꢌꢉꢠꢍꢧꢉꢊꢁꢕꢗꢤꢖꢍꢗ ꢞꢨꢧꢞꢏꢏꢁꢘꢖꢊꢍꢕꢖꢠ
ꢎꢖꢩꢗꢕꢁꢣꢖꢖꢢꢁꢙꢉꢣꢊꢡꢠ
ꢪꢉꢍꢜꢁꢋꢡꢕꢡꢠꢠꢗꢠꢁꢦꢌꢊꢘꢍꢉꢖꢊꢫꢨꢬꢂꢭ
ꢀꢡꢊꢁꢡꢢꢮꢌꢙꢍꢁꢦꢕꢖꢤꢁꢆꢄꢅꢂꢄꢄꢯꢁꢖꢌꢍꢋꢌꢍꢁꢟꢖꢠꢍꢡꢣꢗꢁꢰꢱꢁꢗꢲꢍꢗꢕꢊꢡꢠꢁꢘꢖꢊꢍꢕꢖꢠꢁꢂꢧꢳꢈ
ꢏꢖꢕꢘꢗꢢꢁꢡꢉꢕꢁꢘꢖꢖꢠꢉꢊꢣꢁꢰꢱꢁꢰꢌꢉꢠꢍꢧꢉꢊꢁꢴꢀꢁꢦꢡꢊ
ꢔꢁꢱꢗꢡꢕꢙꢁꢩꢡꢕꢕꢡꢊꢍꢱ
SPECIFICATION
ORDER�NO.
SCP-1K2-05 SCP-1K2-09 SCP-1K2-12 SCP-1K2-15 SCP-1K2-18 SCP-1K2-24 SCP-1K2-36 SCP-1K2-48 SCP-1K2-60
SAFETY MODEL NO.
DC�VOLTAGE
1K2S-P005 1K2S-P009 1K2S-P012 1K2S-P015 1K2S-P018 1K2S-P024 1K2S-P036 1K2S-P048 1K2S-P060
5V
9V
12V
15V
18V
24V
36V
48V
60V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
200A
133A
100A
80A
66A
50A
33A
24A
20A
0�~�200A
1000W
0�~�133A
1200W
100mVp-p
0�~�100A
1200W
120mVp-p
0�~�80A
1200W
150mVp-p
0�~�66A
1200W
180mVp-p
0�~�50A
1200W
240mVp-p
0�~�33A
1200W
360mVp-p
0�~�24A
1152W
480mVp-p
0�~�20A
1200W
500mVp-p
OUTPUT
RIPPLE�&�NOISE�(max.) Note.2 100mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 2.0%
5.0% Typical�adjustment�by�potentiometer����������20%~100%�adjustment�by�1~5VDC�external�control
1.5%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE�REGULATION
0.5%
1.5%
LOAD�REGULATION
SETUP,�RISE,�HOLD�TIME
500ms,�50ms,�16ms�at�full�load
VOLTAGE�RANGE
FREQUENCY RANGE
POWER�FACTOR
180�~�260VAC����������260~370VAC�see�the�derating�curve
47~63Hz
>0.98�/�230VAC
INPUT
EFFICIENCY (Typ.)
AC�CURRENT
80%
82%
84%
85%
86%
89%
89%
90%
90%
10A /�230VAC
60A /�230VAC
INRUSH�CURRENT�(max.)
LEAKAGE�CURRENT (max.) 3.5mA /�240VAC
105~140%�rated�output�power
OVER�LOAD
Note.�4
Protection�type�:�Current�limiting,�delay�shut�down�o/p�voltage,�re-power�on�to�recover
110�~�135% Follow�to�output�set�up�point
PROTECTION OVER�VOLTAGE
Protection�type�:�Shut�down�o/p�voltage,�re-power�on�to�recover
>100 /�measure�by�heat�sink,�near�transformer
OVER�TEMPERATURE
Protection�type�:�Shut�down�o/p�voltage, recovers�automatically�after�temperature�goes�down
-20�~�+65 (Refer�to�output�load�derating�curve)
WORKING�TEMP.
20�~�90%�RH�non-condensing
WORKING�HUMIDITY
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY -20�~�+85
10�~�95%�RH
TEMP.�COEFFICIENT
VIBRATION
0.04%�/ (0�~�50
)
10~200Hz,�2G�10min./1cycle,�60min.�each�along�X, Y,�Z�axes
UL60950, TUV�EN60950 Approved
SAFETY STANDARDS
WITHSTAND�VOLTAGE
ISOLATION�RESISTANCE
EMI�CONDUCTION�&�RADIATION
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
I/P-O/P,�I/P-FG,�OP/FG:100M�Ohms�/�500VDC
Compliance�to�EN55022�(CISPR22)�class A
Compliance�to EN61000-3-2,3
SAFETY &
EMC
(Note.�5)
HARMONIC�CURRENT
EMS�IMMUNITY
POWER�GOOD�SIGNAL
SPECIAL FUNCTION
COOLING
Compliance�to EN61000-4-2,3,4,5,6,8,11,�Light�industry�level,��criteria A
Open�collector�of�NPN�transistor
DC�Voltage Adj.,�remote�sensing,�remote�control,�parallel�operation(refer�to�control�terminal�instruction�manual)
By�fan,�>20%�load�or�>50 fan�on
OTHERS
NOTE
MTBF
37.4K�hrs�min.����MIL-HDBK-217F(25
290*120*132mm�(L*W*H)
)
DIMENSION
PACKING
4.5kg;��4pcs�/19kg�/CARTON
ꢂꢑꢁ�ꢠꢠꢁꢋꢡꢕꢡꢤꢗꢍꢗꢕꢙꢁꢨꢞꢵꢁꢙꢋꢗꢘꢉꢡꢠꢠꢱꢁꢤꢗꢊꢍꢉꢖꢊꢗꢢꢁꢡꢕꢗꢁꢤꢗꢡꢙꢌꢕꢗꢢꢁꢡꢍꢁꢆꢔꢄꢈ�ꢀꢁꢉꢊꢋꢌꢍꢶꢁꢕꢡꢍꢗꢢꢁꢠꢖꢡꢢꢁꢡꢊꢢꢁꢆꢳ ꢖꢦꢁꢡꢤꢰꢉꢗꢊꢍꢁꢍꢗꢤꢋꢗꢕꢡꢍꢌꢕꢗꢑ
ꢆꢑꢁꢷꢉꢋꢋꢠꢗꢁꢸꢁꢊꢖꢉꢙꢗꢁꢡꢕꢗꢁꢤꢗꢡꢙꢌꢕꢗꢢꢁꢡꢍꢁꢆꢄꢹꢺꢻꢁꢖꢦꢁꢰꢡꢊꢢꢩꢉꢢꢍꢜꢁꢰꢱꢁꢌꢙꢉꢊꢣꢁꢡꢁꢂꢆꢼꢁꢍꢩꢉꢙꢍꢗꢢꢁꢋꢡꢉꢕꢧꢩꢉꢕꢗꢁꢍꢗꢕꢤꢉꢊꢡꢍꢗꢢꢁꢩꢉꢍꢜꢁꢡꢁꢄꢑꢂꢌꢦꢁꢸꢁꢽꢾꢌꢦꢁꢋꢡꢕꢡꢠꢠꢗꢠꢁꢘꢡꢋꢡꢘꢉꢍꢖꢕꢑ
ꢔꢑꢁꢵꢖꢠꢗꢕꢡꢊꢘꢗꢁꢚꢁꢉꢊꢘꢠꢌꢢꢗꢙꢁꢙꢗꢍꢁꢌꢋꢁꢍꢖꢠꢗꢕꢡꢊꢘꢗꢶꢁꢠꢉꢊꢗꢁꢕꢗꢣꢌꢠꢡꢍꢉꢖꢊꢁꢡꢊꢢꢁꢠꢖꢡꢢꢁꢕꢗꢣꢌꢠꢡꢍꢉꢖꢊꢑ
ꢽꢑꢁꢀꢌꢕꢕꢗꢊꢍꢁꢠꢉꢤꢉꢍꢉꢊꢣꢁꢔꢁꢍꢉꢤꢗꢙꢫꢂꢑꢳꢙꢶꢔꢑꢄꢙꢶꢳꢑꢄꢙꢭꢵꢜꢗꢊꢁꢉꢊꢍꢗꢠꢠꢉꢣꢗꢊꢍꢁꢡꢌꢍꢖꢁꢕꢗꢘꢖꢟꢗꢕꢱꢁꢰꢗꢦꢖꢕꢗꢁꢙꢜꢌꢍꢁꢢꢖꢩꢊ
ꢳꢑꢁꢵꢜꢗꢁꢋꢖꢩꢗꢕꢁꢙꢌꢋꢋꢠꢱꢁꢉꢙꢁꢘꢖꢊꢙꢉꢢꢗꢕꢗꢢꢁꢡꢁꢘꢖꢤꢋꢖꢊꢗꢊꢍꢁꢩꢜꢉꢘꢜꢁꢩꢉꢠꢠꢁꢰꢗꢁꢉꢊꢙꢍꢡꢠꢠꢗꢢꢁꢉꢊꢍꢖꢁꢡꢁꢦꢉꢊꢡꢠꢁꢗꢿꢌꢉꢋꢤꢗꢊꢍꢑꢁꢵꢜꢗꢁꢦꢉꢊꢡꢠꢁꢗꢿꢌꢉꢋꢤꢗꢊꢍꢁꢤꢌꢙꢍꢁꢰꢗꢁꢕꢗꢧꢘꢖꢊꢦꢉꢕꢤꢗꢢꢁꢍꢜꢡꢍꢁꢉꢍꢁꢙꢍꢉꢠꢠꢁꢤꢗꢗꢍꢙ
ꣀꢹꢀꢁꢢꢉꢕꢗꢘꢍꢉꢟꢗꢙꢑ
300 Myles Standish Blvd., Taunton, MA 02780
WWW.ASTRODYNE.COM
ph: 1-800-823-8082
Fax: 508-823-8181